Different methods of creatinine measurement significantly affect MELD scores

被引:127
作者
Cholongitas, Evangelos
Marelli, Laura
Kerry, Andrew
Senzolo, Marco
Goodier, David W.
Nair, Devaki
Thomas, Michael
Patch, David
Burroughs, Andrew K.
机构
[1] Royal Free Hosp, Liver Transplantat & Hepatobiliary Med Unit, London NW3 2QG, England
[2] Royal Free Hosp, Dept Clin Biochem, London NW3 2QG, England
关键词
D O I
10.1002/lt.20994
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Bilirubin (Bil) interferes with creatinine (Cr) measurement. Different laboratory methods are used to overcome this problem. Model for end-stage liver disease (MELD) scoring incorporates Cr and is used to prioritize patients for liver transplantation. Thus, MELD scores may vary with different Cr measurements influencing patients' priority. Our aim was to evaluate 4 different Cr assays (O'Leary modified Jaffe [mJCr], compensated [rate blanked] kinetic Jaffe [cJCr], enzymatic [ECr], and standard kinetic Jaffe [JCr]) in patients with abnormal liver function tests and assess changes in MELD score. A total of 403 consecutive samples from 158 patients' Cr assays were evaluated.. Bland-Altman plots and MELD scores were also evaluated for each assay. Agreement was found to be poor among all Cr assays. Increased variability in Cr occurred with increasing Bil concentrations: Bil <100 mu mol/L <= 3-point MELD variation - 3-point difference in 2%; Bil >= 400 mu mol/L <= 7-point MELD variation - >= 3-point difference in 78%. When MELD was >= 25 (mJCr as reference; mean, 30.5 points), MELD variation was greatest: mean, 28 (MELD cJCr), 27.5 (MELD ECr), and 28.4 (MELD JCr) (P < 0.001). In conclusion, there is poor agreement among different assays for Cr. As Bil concentration rises, there is greater variability in each creatinine measurements and thus greater variability in MELD scores that, this affect prioritization for liver transplantation.
引用
收藏
页码:523 / 529
页数:7
相关论文
共 29 条
[1]
Arjal R, 2005, HEPATOLOGY, V42, p205A
[2]
Comparison between the enzymatic Vitros assay for creatinine determination and three other methods adapted on the Olympus analyzer [J].
Badiou, S ;
Dupuy, AM ;
Descomps, B ;
Cristol, JP .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2003, 17 (06) :235-240
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
ELIMINATION OF BILIRUBIN INTERFERENCE IN CREATININE ASSAYS BY ROUTINE TECHNIQUES - COMPARISONS WITH A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD [J].
BOOT, S ;
LAROCHE, N ;
LEGG, EF .
ANNALS OF CLINICAL BIOCHEMISTRY, 1994, 31 :262-266
[5]
MELD underestimated unless enzymatic creatinine used [J].
Bzowej, NH ;
Huilgol, VR ;
Sebanc, H ;
Bonacini, M ;
Rabkin, J ;
Doo, E ;
Hisitake, G ;
Hassoun, A ;
Wakil, AS ;
Osorio, R ;
Gish, RG .
JOURNAL OF HEPATOLOGY, 2004, 40 :40-40
[6]
Systematic review: the model for end-stage liver disease - should it replace Child-Pugh's classification for assessing prognosis in cirrhosis? [J].
Cholongitas, E ;
Papatheodoridis, GV ;
Vangeli, M ;
Terreni, N ;
Patch, D ;
Burroughs, AK .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2005, 22 (11-12) :1079-1089
[7]
MELD is not enough - enough of MELD? [J].
Cholongitas, E ;
Senzolo, M ;
Triantos, C ;
Samonakis, D ;
Patch, D ;
Burroughs, AK .
JOURNAL OF HEPATOLOGY, 2005, 42 (04) :475-477
[8]
CHOLONGITAS E, IN PRESS AM J TRANSP
[9]
Prognostic models including the Child-Pugh, MELD and Mayo risk scores - where are we and where should we go? [J].
Christensen, E .
JOURNAL OF HEPATOLOGY, 2004, 41 (02) :344-350
[10]
Decline in muscle mass with age in women: A longitudinal study using an indirect measure [J].
Davies, KM ;
Heaney, RP ;
Rafferty, K .
METABOLISM-CLINICAL AND EXPERIMENTAL, 2002, 51 (07) :935-939