Electromagnetic calorimeters for the BNL muon (g-2) experiment

被引:48
作者
Sedykh, SA
Blackburn, JR
Bunker, BD
Debevec, PT
Gray, FE
Hertzog, DW
Jones, TD
Onderwater, CJG
Polly, CC
Urner, DC
Carey, RM
Coulsey, C
de Santi, G
Hare, M
Miller, JP
Ouyang, J
Rind, O
Trofimov, A
Cushman, P
Giron, S
Kindem, J
Timmermans, C
Zimmerman, D
Winn, D
Druzhinin, V
机构
[1] Univ Illinois, Dept Phys, Loomis Lab Phys 469, Urbana, IL 61801 USA
[2] Boston Univ, Dept Phys, Boston, MA 02215 USA
[3] Univ Minnesota, Dept Phys, Minneapolis, MN 55455 USA
[4] Fairfield Univ, Dept Phys, Fairfield, CT 06430 USA
[5] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
基金
美国国家科学基金会;
关键词
electromagnetic calorimeter; lead scintillating fiber;
D O I
10.1016/S0168-9002(00)00576-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A set of 24 lead/scintillating fiber electromagnetic calorimeters has been constructed for the new muon (g - 2) experiment at the Brookhaven AGS. These calorimeters were designed to provide very good energy resolution for electrons up to 3 GeV while also yielding excellent timing information. Special requirements in the experiment related to the uniformity of response, the short-term gain and timing stability, and the neutron background led to several unusual design features. The calorimeters were tested and calibrated with electrons in the energy range 0.5-4.0 GeV and have been installed and used in the muon storage ring. The design criteria, construction, and performance of the system are described. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:346 / 360
页数:15
相关论文
共 10 条
[1]   FINAL REPORT ON THE CERN MUON STORAGE RING INCLUDING THE ANOMALOUS MAGNETIC-MOMENT AND THE ELECTRIC-DIPOLE MOMENT OF THE MUON, AND A DIRECT TEST OF RELATIVISTIC TIME DILATION [J].
BAILEY, J ;
BORER, K ;
COMBLEY, F ;
DRUMM, H ;
ECK, C ;
FARLEY, FJM ;
FIELD, JH ;
FLEGEL, W ;
HATTERSLEY, PM ;
KRIENEN, F ;
LANGE, F ;
LEBEE, G ;
MCMILLAN, E ;
PETRUCCI, G ;
PICASSO, E ;
RUNOLFSSON, O ;
RUDEN, WV ;
WILLIAMS, RW ;
WOJCICKI, S .
NUCLEAR PHYSICS B, 1979, 150 (01) :1-75
[2]  
*BNL AGS, 1995, E821 BNL AGS
[3]   New measurement of the anomalous magnetic moment of the positive muon [J].
Carey, RM ;
Earle, W ;
Efstathiadis, E ;
Hare, MF ;
Hazen, ES ;
Hughes, BJ ;
Krienen, F ;
Miller, JP ;
Monich, V ;
Ouyang, J ;
Rind, O ;
Roberts, BL ;
Sulak, LR ;
Trofimov, A ;
Varner, G ;
Worstell, WA ;
Benedict, E ;
Logashenko, I ;
Benante, J ;
Brown, HN ;
Bunce, G ;
Cullen, J ;
Danby, GT ;
Geller, J ;
Hseuh, H ;
Jackson, JW ;
Jia, L ;
Kochis, S ;
Larsen, R ;
Lee, YY ;
Mapes, M ;
Meng, W ;
Morse, WM ;
Pai, C ;
Pearson, C ;
Polk, I ;
Prigl, R ;
Rankowitz, S ;
Sandberg, J ;
Semertzidis, YK ;
Shutt, R ;
Snydstrup, L ;
Soukas, A ;
Stillman, A ;
Tallerico, T ;
Tanaka, M ;
Toldo, F ;
von Lintig, D ;
Warburton, D ;
Woodle, K .
PHYSICAL REVIEW LETTERS, 1999, 82 (08) :1632-1635
[4]   A high efficiency tile-fiber hodoscope read out by multichannel phototubes [J].
Cushman, P ;
Giron, S ;
Kindem, J ;
Maxam, D ;
Miller, D ;
Timmermans, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (1-2) :116-130
[5]  
DANBY GH, 2000, IN PRESS NUCL INSTR
[6]  
EFSTATHIADIS E, 1998, G 2 MUON KICKER SPEC
[7]  
FABJAN C, 1991, EXPT TECHNIQUES HIGH, P257
[8]   A HIGH-RESOLUTION LEAD SCINTILLATING FIBER ELECTROMAGNETIC CALORIMETER [J].
HERTZOG, DW ;
DEBEVEC, PT ;
EISENSTEIN, RA ;
GRAHAM, MA ;
HUGHES, SA ;
REIMER, PE ;
TAYLOE, RL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (03) :446-458
[9]  
SEMERTZIDIS Y, UNPUB NUCL INSTR MET
[10]   MODELING AND SCANNING OF LIGHTGUIDES FOR PB/SCIFI CALORIMETERS [J].
SIMON, DA ;
HERTZOG, DW ;
JONES, TD ;
RHODES, MW ;
YAIRI, MB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2) :86-101