Benefits of stereopsis when identifying clinically significant macular edema via teleophthalmology

被引:23
作者
Rudnisky, Christopher J.
Tennant, Matthew T. S.
de Leon, Alexander R.
Hinz, Bradley J.
Greve, Mark D. J.
机构
[1] Univ Alberta, Dept Ophthalmol, Edmonton, AB T6G 2M7, Canada
[2] Univ Calgary, Dept Math & Stat, Calgary, AB T2N 1N4, Canada
来源
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | 2006年 / 41卷 / 06期
关键词
teleophthalmology; telemedicine; stereopsis; diabetic retinopathy; macular edema;
D O I
10.1139/I06-066
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The need to incorporate stereopsis into a teleophthalmology system is controversial. Detection of hard exudate in the macula is suggested by some as an adequate surrogate for direct observation of retinal thickening. This study was designed to determine how accurate the detection of hard exudate is as a surrogate for,stereoscopic detection of clinically significant macular edema (CSME). Methods: 120 patients with diabetes underwent clinical retinal examination with contact-lens biomicroscopy by a retinal specialist. The presence or absence of CSME was recorded. On the same day as clinical grading, 30 degrees stereoscopic digital photographs of the macula were captured. At least 2 months after clinical examination, the digital images were viewed by masked graders for the presence or absence of hard exudate and retinal thickening. Results: 207 eyes of 106 patients had complete data sets for both diagnostic modalities. The sensitivity of hard exudate (93.9%) in predicting the presence of CSME was similar to that of direct stereoscopic observation of retinal thickening (90.9%), with p = 0.5. On the other hand, digital stereopsis was significantly more specific (92.9%) than was hard exudate (81.6%) in predicting the presence of CSME (p < 0.001). This difference was maintained even when controlling for image quality. Interpretation:Although the presence of hard exudate within the macula is a sensitive surrogate marker for CSME, it is less specific than stereoscopic evaluation. Any American Telemedicine Association category 3 teleophthalmology system that utilizes hard exudate as a surrogate marker for CSME may refer patients unnecessarily for clinical evaluation.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 22 条
[1]   A screening approach to the surveillance of patients with diabetes for the presence of vision-threatening retinopathy [J].
Bresnick, GH ;
Mukamel, DB ;
Dickinson, JC ;
Cole, DR .
OPHTHALMOLOGY, 2000, 107 (01) :19-24
[2]   Detection of diabetic foveal edema - Contact lens biomicroscopy compared with optical coherence tomography [J].
Brown, JC ;
Solomon, SD ;
Bressler, SB ;
Schachat, AP ;
DiBernardo, C ;
Bressler, NM .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (03) :330-335
[3]   Comparison of the clinical diagnosis of diabetic macular edema with diagnosis by optical coherence tomography [J].
Browning, DJ ;
McOwen, MD ;
Bowen, RM ;
O'Marah, TL .
OPHTHALMOLOGY, 2004, 111 (04) :712-715
[4]  
*CA DIAB ASS CLIN, 2003, CAN J DIABETES, V27, pS76
[5]   Sample-size calculations for Cohen's kappa [J].
Cantor, AB .
PSYCHOLOGICAL METHODS, 1996, 1 (02) :150-153
[6]   Emerging trends in ocular telemedicine: the diabetic retinopathy model [J].
Cavallerano, J ;
Aiello, LM .
JOURNAL OF TELEMEDICINE AND TELECARE, 2005, 11 (04) :163-166
[7]  
Early Treatment Diabetic Retinopathy Study Res Grp, 1991, OPHTHALMOLOGY, V98, P766
[8]  
Early Treatment of Diabetic Retinopathy Study Research Group, 1987, INT OPHTHALMOL CLIN, V27, P265
[9]  
Four risk factors for severe visual loss in diabetic retinopathy, 1979, ARCH OPHTHALMOL-CHIC, V97, P654
[10]   The relation of retinal vessel caliber to the incidence and progression of diabetic retinopathy - XIX: The Wisconsin epidemiologic study of diabetic retinopathy [J].
Klein, R ;
Klein, BEK ;
Moss, SE ;
Wong, TY ;
Hubbard, L ;
Cruickshanks, KJ ;
Palta, M .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (01) :76-83