Mitral valve opening in the ovine heart

被引:48
作者
Karlsson, MO
Glasson, JR
Bolger, AF
Daughters, GT
Komeda, M
Foppiano, LE
Miller, DC
Ingels, NB
机构
[1] Palo Alto Med Fdn, Res Inst, Dept Cardiovasc Physiol & Biophys, Palo Alto, CA 94301 USA
[2] Linkoping Univ, Dept Mech Engn, S-58183 Linkoping, Sweden
[3] Stanford Univ, Sch Med, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[4] Stanford Univ, Sch Med, Dept Cardiovasc Med, Stanford, CA 94305 USA
[5] Stanford Univ, Sch Med, Dept Anesthesia, Stanford, CA 94305 USA
[6] Dept Vet Affairs Med Ctr, Cardiac Surg Sect, Palo Alto, CA 94304 USA
[7] Dept Vet Affairs Med Ctr, Cardiol Sect, Palo Alto, CA 94304 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1998年 / 274卷 / 02期
关键词
leaflets; annulus; radiopaque markers; coaptation; sheep;
D O I
10.1152/ajpheart.1998.274.2.H552
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To study the three-dimensional size, shape, and motion of the mitral leaflets and annulus, we surgically attached radiopaque markers to sites on the mitral annulus and leaflets in seven sheep. After 8 days of recovery, the animals were sedated, and three-dimensional marker positions were measured by computer analysis of biplane videofluorograms (60/s), We found that the oval mitral annulus became most elliptical in middiastole. Both leaflets began to descend into the left ventricle (LV) during the rapid fall of LV pressure (LVP), before leaflet edge separation. The anterior leaflet exhibited a compound curvature in systole and maintained this shape during opening. The central cusp of the posterior leaflet was curved slightly concave to the LV during opening. Markers al the border of the "rough zone" were separated by 10 mm during systole. We conclude that coaptation occurs very near the leaflet edges, that the annulus and leaflets move toward their open positions during the rapid fall of LVP, and that leaflet edge separation, the last event in the opening sequence, occurs near the tints of minimum LVP.
引用
收藏
页码:H552 / H563
页数:12
相关论文
共 35 条
[1]  
Antunes MJ, 1989, Mitral Valve Repair
[2]  
BRAUNWALD E, 1988, HEART DISEASE TXB CA, P1034
[3]   MITRAL-VALVE RING IN NORMAL VS DILATED LEFT-VENTRICLE - CROSS-SECTIONAL ECHOCARDIOGRAPHIC STUDY [J].
CHANDRARATNA, PAN ;
ARONOW, WS .
CHEST, 1981, 79 (02) :151-154
[4]  
DAUGHTERS GT, 1989, IEEE COMPUT SOC PRES, V15, P79
[5]  
DAVIS PKB, 1963, J CARDIOVASC SURG, V4, P427
[6]   Mechanism of mitral leaflet excursion [J].
Dent, JM ;
Spotnitz, WD ;
Nolan, SP ;
Jayaweera, AR ;
Glasheen, WP ;
Kaul, S .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (06) :H2100-H2108
[7]   Three-dimensional regional dynamics of the normal mitral anulus during left ventricular ejection [J].
Glasson, JR ;
Komeda, M ;
Daughters, GT ;
Niczyporuk, MA ;
Bolger, AF ;
Ingels, NB ;
Miller, DC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (03) :574-584
[8]  
HINDS JE, 1969, FED PROC, V28, P1351
[9]   MEASUREMENT OF MIDWALL MYOCARDIAL DYNAMICS IN INTACT MAN BY RADIOGRAPHY OF SURGICALLY IMPLANTED MARKERS [J].
INGELS, NB ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL .
CIRCULATION, 1975, 52 (05) :859-867
[10]   MORPHOLOGY OF HUMAN MITRAL VALVE .1. CHORDAE TENDINEAE - A NEW CLASSIFICATION [J].
LAM, JHC ;
RANGANATHAN, N ;
WIGLE, ED .
CIRCULATION, 1970, 41 (03) :449-+