Imaging assessment of sacroiliac screw placement relative to the neuroforamen

被引:22
作者
Goldberg, BA
Lindsey, RW
Foglar, C
Hedrick, TD
Miclau, T
Hadad, JL
机构
[1] Baylor Coll Med, Barnhart Dept Orthopaed Surg, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[3] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Orthopaed Surg, San Francisco, CA USA
关键词
computed tomography; neuroforamen; sacroiliac screw;
D O I
10.1097/00007632-199803010-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Twenty-four cannulated sacroiliac screws were placed bilaterally into 12 cadaveric pelvi (12 titanium screws and 12 stainless-steel screws) and were imaged using conventional and multiplanar reconstructed computed tomography. Objectives. To determine whether sacroiliac screw position assessment relative to the neuroforamen is enhanced by: 1) computed tomography using multiplanar reconstructions and 2) the use of titanium screws rather than stainless-steel screws. Summary of Background Data. To the authors' knowledge, there have been no prior studies demonstrating the accuracy of multiplanar computed tomography compared with that of conventional (axial) tomography in determining the position of sacroiliac screws relative to the neuroforamen. Although titanium screws have been shown to have less scatter than stainless-steel screws, the effect of alloy composition on the radiographic accuracy of interpreting the screw position relative to the sacral neuroforamen is unknown. Methods, Screws were deliberately placed into: position A, in which the screw did not violate the neuroforamen; position B, in which the threads of the screw came within 3 mm of the neuroforamen; and position C, in which the screw clearly was nearly centered in the neuroforamen. The degrees of accuracy in assessing screw position relative to the neuroforamen using conventional (axial) images and using multiplanar reconstructed images were compared. Results. The axial images were accurate in determining screw position relative to the neuroforamen in 50% of cases in which titanium screws were used and in 42% of cases in which stainless-steel screws were used. The corresponding values for multiplanar reconstructions were 92% for cases in which titanium screws were used and 67% for cases in which stainless-steel screws were used. The accuracy of multiplanar reconstructions was statistically better than that of axial images (P < 0.05). Metallic scatter was increased in stainless-steel screws. Conclusion. The results of this study suggest that the use of computed tomography with multiplanar reconstruction improves accuracy in determining sacroiliac screw position relative to the neuroforamen. The assessment of screw position may be facilitated using titanium screws.
引用
收藏
页码:585 / 589
页数:5
相关论文
共 15 条
[1]
Daum W J, 1991, J Orthop Trauma, V5, P34, DOI 10.1097/00005131-199103000-00006
[2]
ANATOMIC AND EXPERIMENTAL BASIS FOR THE INSERTION OF A SCREW AT THE 1ST SACRAL VERTEBRA [J].
DEPERETTI, F ;
ARGENSON, C ;
BOURGEON, A ;
OMAR, F ;
EUDE, P ;
ABOULKER, C .
SURGICAL AND RADIOLOGIC ANATOMY, 1991, 13 (02) :133-137
[3]
EBRAHEIM NA, 1993, ORTHOPEDICS, V16, P616
[4]
EBRAHEIM NA, 1990, ORTHOPEDICS, V13, P1357
[5]
EBRAHEIM NA, 1994, SPINE, V19, P721
[6]
TECHNIQUE AND RESULTS OF FIXATION TO THE SACRUM WITH ILIOSACRAL SCREWS [J].
FARCY, JPC ;
RAWLINS, BA ;
GLASSMAN, SD .
SPINE, 1992, 17 (06) :S190-S195
[7]
POSTERIOR SACROILIAC FIXATION USING A SACRAL PEDICLE TARGETING DEVICE - AN ANATOMICAL STUDY [J].
MILLER, MD ;
CAIN, JE ;
LAUERMAN, WC ;
LITTLEFIELD, WG ;
PLATENBERG, RC ;
WILSON, MR .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (06) :514-520
[8]
PREOPERATIVE CT DETERMINATION OF ANGLES FOR SACRAL SCREW PLACEMENT [J].
MORSE, BJ ;
EBRAHEIM, NA ;
JACKSON, WT .
SPINE, 1994, 19 (05) :604-607
[9]
CT-GUIDED FIXATION OF SACRAL FRACTURES AND SACROILIAC JOINT DISRUPTIONS [J].
NELSON, DW ;
DUWELIUS, PJ .
RADIOLOGY, 1991, 180 (02) :527-532
[10]
ROUTT MLC, 1995, J ORTHOP TRAUMA, V9, P207