Atmospheric pressure ionization and liquid chromatography mass spectrometry - Together at last

被引:51
作者
Thomson, BA [1 ]
机构
[1] PE SCIEX, Concord, ON L4K 4V8, Canada
关键词
D O I
10.1016/S1044-0305(97)00285-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The evolution of atmospheric pressure ionization techniques which are now routinely applied as liquid chromatograph/mass spectrometer (LC/MS) interfaces is described. Electrospray and related methods, as well as atmospheric pressure chemical ionization combined with the heated nebulizer interface, both began as specialized ionization techniques which became much more widely accepted when combined with tandem mass spectrometry. Today, both are widely used for quantitative and qualitative LC/MS and LC/MS/MS analyses. Important events in the development of these methods are described, along with key elements in the evolution of the ion source-to-vacuum interface techniques that contributed to their success. (C) 1998 American Society for Mass Spectrometry.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 34 条
  • [1] ARPINO P J, 1982, Trends in Analytical Chemistry, V1, P154, DOI 10.1016/0165-9936(82)80049-6
  • [2] DETERMINATION OF SULFONATED AZO DYES BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    WEIDOLF, LOG
    HENION, JD
    BUDDE, WL
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2647 - 2652
  • [3] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [4] ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    HAEGELE, KD
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (14) : 2369 - 2373
  • [5] AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES
    CHOWDHURY, SK
    KATTA, V
    CHAIT, BT
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) : 81 - 87
  • [6] HIGH-SPEED LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY FOR THE DETERMINATION OF DRUGS IN BIOLOGICAL SAMPLES
    COVEY, TR
    LEE, ED
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (12) : 2453 - 2460
  • [7] CROWTHER JB, 1985, LC MAG, V3, P240
  • [8] COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES
    DOUGLAS, DJ
    FRENCH, JB
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) : 398 - 408
  • [9] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [10] FRENCH JB, 1979, Patent No. 4137750