Flexible ureteroscopes: A single center evaluation of the durability and function of the new endoscopes smaller than 9Fr

被引:145
作者
Afane, JS [1 ]
Olweny, EO
Bercowsky, E
Sundaram, CP
Dunn, MD
Shalhav, AL
McDougall, EM
Clayman, RV
机构
[1] Washington Univ, Sch Med, Dept Surg, Div Urol Surg, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
[3] Univ So Calif, Kenneth Norris Canc Hosp, Dept Urol, Los Angeles, CA USA
[4] Indiana Univ, Med Ctr, Dept Urol, Indianapolis, IN USA
[5] Vanderbilt Univ, Med Ctr, Dept Urol Surg, Nashville, TN USA
关键词
ureter; kidney; ureteral calculi; kidney calculi; ureteroscopy;
D O I
10.1016/S0022-5347(05)67133-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Flexible ureteroscopes smaller than 9Fr are widely used in endourology. We systematically evaluated the functional durability of these instruments in the clinical setting. Materials and Methods: We performed ureteronephroscopy 92 consecutive times in 84 patients at our hospital using a flexible Storz model 11274AA,(+)(+) Circon-ACMI model. AUR-7, Wolf model 7325.172\\ and Olympus model URF/P3 ureteroscope . Preoperatively and postoperatively we evaluated all flexible ureteroscopes for luminosity, irrigant flow at 100 mm. Hg, number of broken image fibers and active deflection range. During the procedure a record was kept of the duration that the endoscope remained in the urinary tract, average irrigation pressure, method of insertion, various devices used within the working channel, need for lower pole access, and surgeon overall impression of visibility and maneuverability. Results: The luminosity and irrigant flow of all endoscopes remained relatively unchanged during consecutive applications, while active deflection deteriorated 2% to 28%. Endoscopes were used for an average of 3 to 13 hours before they needed repair. The most fragile part of these instruments was the deflection unit. Conclusions: Small diameter flexible ureteroscopes are effective for diagnosing and treating upper urinary tract pathology but improved durability is required. Currently they represent a highly effective but high maintenance means of achieving retrograde access to the ureter and kidney with a need for repair after only 6 to 15 uses.
引用
收藏
页码:1164 / 1168
页数:5
相关论文
共 11 条
[1]   URETERAL ENDOSCOPY WITH PASSIVELY DEFLECTABLE, IRRIGATING FLEXIBLE URETEROSCOPES [J].
BAGLEY, DH .
UROLOGY, 1987, 29 (02) :170-173
[2]   COMBINED RIGID AND FLEXIBLE URETEROPYELOSCOPY [J].
BAGLEY, DH ;
HUFFMAN, JL ;
LYON, ES .
JOURNAL OF UROLOGY, 1983, 130 (02) :243-244
[3]   FLEXIBLE URETEROPYELOSCOPY - DIAGNOSIS AND TREATMENT IN THE UPPER URINARY-TRACT [J].
BAGLEY, DH ;
HUFFMAN, JL ;
LYON, ES .
JOURNAL OF UROLOGY, 1987, 138 (02) :280-285
[4]   Flexible ureteroscopy: Washington University experience with the 9.3F and 7.5F flexible ureteroscopes [J].
Elashry, OM ;
Elbahnasy, AM ;
Rao, GS ;
Nakada, SY ;
Clayman, RV .
JOURNAL OF UROLOGY, 1997, 157 (06) :2074-2080
[5]   A 7.5 8.2 F ACTIVELY DEFLECTABLE, FLEXIBLE URETEROSCOPE - A NEW DEVICE FOR BOTH DIAGNOSTIC AND THERAPEUTIC UPPER URINARY-TRACT ENDOSCOPY [J].
GRASSO, M ;
BAGLEY, D .
UROLOGY, 1994, 43 (04) :435-441
[6]   Small diameter, actively deflectable, flexible ureteropyeloscopy [J].
Grasso, M ;
Bagley, D .
JOURNAL OF UROLOGY, 1998, 160 (05) :1648-1653
[7]   FIBER OPTICS IN UROLOGY [J].
MARSHALL, VF .
JOURNAL OF UROLOGY, 1964, 91 (01) :110-&
[8]  
TAKAGI T, 1968, SURGERY, V64, P1033
[9]   CLINICAL APPLICATION OF FIBER-OPTIC PYELOURETEROSCOPE [J].
TAKAYASU, H ;
ASO, Y ;
TAKAGI, T ;
GO, T .
UROLOGIA INTERNATIONALIS, 1971, 26 (02) :97-&
[10]   RECENT DEVELOPMENT FOR PYELOURETEROSCOPY - GUIDE TUBE METHOD FOR ITS INTRODUCTION INTO URETER [J].
TAKAYASU, H ;
ASO, Y .
JOURNAL OF UROLOGY, 1974, 112 (02) :176-178