Organophosphate flame retardants and plasticizers in indoor air

被引:198
作者
Hartmann, PC
Bürgi, D
Giger, W
机构
[1] EAWAG, Swiss Fed Inst Environm Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] Friedli Geotech AG, CH-8008 Zurich, Switzerland
关键词
TCEP; TCPP; risk assessment; TBEP; health;
D O I
10.1016/j.chemosphere.2004.08.051
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Analytical methods were developed for a broad range of organophosphate flame retardants and plasticizers in indoor air. Screening was performed of various indoor environments at 12 locations in and around Zurich, Switzerland. Method recoveries ranged from 62% for triphenyl phosphate to 100% for tris(2-ethylhexyl) phosphate. Tris(2-chloro-isopropyl) phosphate was found in the highest concentration (260ng/m(3)) mainly in cars and furniture stores. Tris(2-eth-3 ylhexyl) phosphate and triphenyl phosphate, both up to 3.4 ng/m(3), were also detected in quantifiable concentrations at several sites. Tris(1,3-dichloroisopropyl) phosphate, tricresyl phosphate and tri(2-butoxyethyl) phosphate were below the limit of quantification in all samples. The results of the risk assessment indicate that the observed concentrations are below the predicted threshold for human health effects. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 29 条
[1]  
*BAG, 2001, BAG INTERNES PRODUKT
[2]   ALLERGIC CONTACT-DERMATITIS FROM TRIPHENYL PHOSPHATE [J].
CAMARASA, JG ;
SERRABALDRICH, E .
CONTACT DERMATITIS, 1992, 26 (04) :264-265
[3]   Video display units: An emission source of the contact allergenic flame retardant triphenyl phosphate in the indoor environment [J].
Carlsson, H ;
Nilsson, U ;
Ostman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (18) :3885-3889
[4]   Organophosphate ester flame retardants and plasticizers in the indoor environment: Analytical methodology and occurrence [J].
Carlsson, H ;
Nilsson, U ;
Becker, G ;
Ostman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (10) :2931-2936
[5]  
CHO KJ, 1994, WATER SCI TECHNOL, V30, P189
[6]  
DAVENPORT B, 2002, FLAME RETARDANTS
[7]   Analysis of organophosphate hydraulic fluids in US Air Force base soils [J].
David, MD ;
Seiber, JN .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1999, 36 (03) :235-241
[8]  
European Commission, 1996, Technical guidance document in support of Commission directive on risk assessment for new notified substances and Commission regulation (EC) no. 1488 94 on risk assessment for existing substances
[9]   Occurrence of organophosphate esters in surface water and ground water in Germany [J].
Fries, E ;
Püttmann, W .
JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (06) :621-626
[10]   SEDIMENT ANALYSIS FOR THE ASSESSMENT OF RISK FROM ORGANIC POLLUTANTS IN LAKES [J].
GALASSI, S ;
PROVINI, A ;
GAROFALO, E .
HYDROBIOLOGIA, 1992, 235 :639-647