ULTRASOUND-TRIGGERED RELEASE OF RECOMBINANT TISSUE-TYPE PLASMINOGEN ACTIVATOR FROM ECHOGENIC LIPOSOMES

被引:74
作者
Smith, Denise A. B. [1 ,2 ]
Vaidya, Sampada S. [2 ]
Kopechek, Jonathan A. [2 ]
Huang, Shao-Ling [3 ]
Klegerman, Melvin E. [3 ]
Mcpherson, David D. [3 ]
Holland, Christy K. [2 ]
机构
[1] Univ Cincinnati, Div Vasc Surg, Dept Surg, Coll Med, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH 45267 USA
[3] Univ Texas Hlth Sci Ctr, Div Cardiol, Dept Internal Med, Houston, TX USA
基金
美国国家卫生研究院;
关键词
Ultrasound-enhanced thrombolysis; Drug delivery; Therapeutic ultrasound; Echogenic liposomes; Ultrasound contrast agents; Destruction thresholds; GENE DELIVERY; CONTRAST; DRUG; REFLECTIVITY; STABILITY; THROMBOLYSIS; MICROBUBBLES; DISPERSIONS; AGENTS;
D O I
10.1016/j.ultrasmedbio.2009.08.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Echogenic liposomes (ELIP) were developed as ultrasound-triggered targeted drug or gene delivery vehicles (Lanza et al. 1997; Huang et al. 2001). Recombinant tissue-type plasminogen activator (rt-PA), a thrombolytic, has been loaded into ELIP (Tiukinhoy-Laing et al. 2007). These vesicles have the potential to be used for ultrasound-enhanced thrombolysis in the treatment of acute ischemic stroke, myocardial infarction, deep vein thrombosis or pulmonary embolus. A clinical diagnostic ultrasound scanner (Philips HDI 5000; Philips Medical Systems, Bothell, WA, USA) equipped with a linear array transducer (L12-5) was employed for in vitro studies using rt-PA-loaded ELIP (T-ELIP). The goal of this study was to quantify ultrasound-triggered drug release from rt-PA-loaded echogenic liposomes. T-ELIP samples were exposed to 6.9-MHz B-mode pulses at a low pressure amplitude (600 kPa) to track the echogenicity over time under four experimental conditions: (1) flow alone to monitor gas diffusion from the T-ELIP, (2) pulsed 6.0-MHz color Doppler exposure above the acoustically driven threshold (0.8 MPa) to force gas out of the liposome gently, (3) pulsed 6.0-MHz color Doppler above the rapid fragmentation threshold (2.6 MPa) or (4) Triton X-100 to rupture the T-ELIP chemically as a positive control. Release of rt-PA for each ultrasound exposure protocol was assayed spectrophotometrically. T-ELIP were echogenic in the flow model (5 mL/min) for 30 min. The thrombolytic drug remained associated with the liposome when exposed to low-amplitude B-mode pulses over 60 min and was released when exposed to color Doppler pulses or Triton X-100. The rt-PA released from the liposomes had similar enzymatic activity as the free drug. These T-ELIP are robust and echogenic during continuous fundamental 6.9-MHz B-mode imaging at a low exposure output level (600 kPa). Furthermore, a therapeutic concentration of rt-PA can be released by fragmenting the T-ELIP with pulsed 6.0-MHz color Doppler ultrasound above the rapid fragmentation threshold (1.59 MPa). (E-mail: denise.smith@uc.edu) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:145 / 157
页数:13
相关论文
共 44 条
[1]  
Alexandrov AV., 2006, Seminars in Cerebrovascular Diseases and Stroke, V5, P106
[2]   GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND [J].
APFEL, RE ;
HOLLAND, CK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :179-185
[3]   The influence of fragmentation on the acoustic response from shrinking bubbles [J].
Bevan, Peter D. ;
Karshafian, Raffi ;
Burns, Peter N. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (07) :1152-1162
[4]   Influence of lipid shell physicochemical properties on ultrasound-induced microbubble destruction [J].
Borden, MA ;
Kruse, DE ;
Caskey, CF ;
Zhao, SK ;
Dayton, PA ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (11) :1992-2002
[5]   High-speed optical observations of contrast agent destruction [J].
Bouakaz, A ;
Versluis, M ;
de Jong, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03) :391-399
[6]   WFUMB safety symposium on echo-contrast agents: Nature and types of ultrasound contrast agents [J].
Bouakaz, Ayache ;
de Jong, Nico .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (02) :187-196
[7]   Echogenic liposome compositions for increased retention of ultrasound reflectivity at physiologic temperature [J].
Buchanan, Kyle D. ;
Huang, Shaoling ;
Kim, Hyunggun ;
Macdonald, Robert C. ;
McPherson, David D. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 97 (06) :2242-2249
[8]   Efficient gene delivery to pancreatic islets with ultrasonic microbubble destruction technology [J].
Chen, Shuyuan ;
Ding, Jia-huan ;
Bekeredjian, Raffi ;
Yang, Bing-zhi ;
Shohet, Ralph V. ;
Johnston, Stephen A. ;
Hohmeier, Hans E. ;
Newgard, Christopher B. ;
Grayburn, Paul A. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (22) :8469-8474
[9]   Optimization of ultrasound parameters for cardiac gene delivery of adenoviral or plasmid deoxyribonucleic acid by ultrasound-targeted microbubble destruction [J].
Chen, SY ;
Shohet, RV ;
Bekeredjian, R ;
Frenkel, P ;
Grayburn, PA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (02) :301-308
[10]  
CHMLELEWSKA J, 1986, CLIN CHEM, V32, P482