Comparison of standard capillary and chip separations of sodium dodecylsulfate-protein complexes

被引:18
作者
Deyl, Z [1 ]
Miksík, I [1 ]
Eckhardt, A [1 ]
机构
[1] Acad Sci Czech Republ, Inst Physiol, Prague 14220 4, Czech Republic
关键词
complexation; chip technology; proteins; sodium dodecylsulfate;
D O I
10.1016/S0021-9673(02)01523-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conditions for converting a set of five standard proteins to electrochemically active sodium dodecylsulfate (SDS) complexes were worked out with the aim of,using such complexes for conductivity detection with a a chip electrophoresis system. The results obtained were compared with standard capillary electrophoresis (37 cm (effective length 30 cm)x75 mum I.D. capillary, 10 W, negative polarity at the inlet). The chip separations were run at 500 V per chip (100 V/cm) as compared to the standard capillary arrangement, which was run at 266.6 V/cm. For the capillary set-up the protein complexes were prepared in aqueous solution (Milli-Q water) made 10 mM with respect to SDS. If the SDS concentration was increased to 50 mM, the separation in the capillary was incomplete. On the other hand with the chip system both approaches yielded acceptable results. The chip separations were slightly (but not distinctly) shorter and offered better separations than the standard set-up. The concentration of the surfactant used for the preparation the complexes results in alternations of the elution sequence, which is preserved if the chip separation is used instead of the capillary set-up. Apparently the full capacity of protein-SDS binding is not exploited for the preparation of the adducts. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 31 条
[1]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[2]  
2-M
[3]   Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry [J].
Chan, JH ;
Timperman, AT ;
Qin, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4437-4444
[4]   Room temperature bonding of micromachined glass devices for capillary electrophoresis [J].
Chiem, N ;
Lockyear-Shultz, L ;
Andersson, P ;
Skinner, C ;
Harrison, DJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :147-152
[5]  
DEYL Z, 1979, ELECTROPHORESIS SU A, P47
[6]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[7]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[8]   Counting single chromophore molecules for ultrasensitive analysis and separations on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Davis, LM ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :431-437
[9]   Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels [J].
Gavin, PF ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3838-3845
[10]  
Guijt RM, 2001, ELECTROPHORESIS, V22, P2537, DOI 10.1002/1522-2683(200107)22:12<2537::AID-ELPS2537>3.0.CO