Evaluation of 14 commercial HIV-1/HIV-2 antibody assays using serum panels of different geographical origin and clinical stage including a unique seroconversion panel

被引:43
作者
Thorstensson, R [1 ]
Andersson, S
Lindbäck, S
Dias, F
Mhalu, F
Gaines, H
Biberfeld, G
机构
[1] Swedish Inst Infect Dis Control, S-10521 Stockholm, Sweden
[2] Karolinska Inst, S-10521 Stockholm, Sweden
[3] Huddinge Univ Hosp, Karolinska Inst, Dept Infect Dis, S-14186 Huddinge, Sweden
[4] Publ Hlth Lab, Bissau, Guinea Bissau
[5] Muhimbili Med Ctr, Dept Microbiol & Immunol, Dar Es Salaam, Tanzania
关键词
D O I
10.1016/S0166-0934(97)00176-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of 14 commercially available HIV-1/2 antibody assays were compared using well-characterized serum panels containing in total 1500-1800 sera. The panels included consecutive HIV-negative blood donor sera from Sweden, unselected blood donor and patient sera from Tanzania and unselected sera from outpatient clinics in Guinea-Bissau. Furthermore selected HIV-1 antibody positive sera from Sweden and Tanzania and HIV-2 antibody positive sera from Guinea-Bissau were included in the panels. The HIV-1 antibody positive sera were from individuals at various stages of HIV infection, from primary infection, to asymptomatic phase and late stage disease. 12 of the 14 assays identified correctly all HIV-1 and HIV-2 antibody positive sera. One Tanzanian HIV-1 antibody positive sample with complete banding pattern on Western blot was not detected by two of the ELISAs employing synthetic peptides. There were small differences in sensitivity between the assays when used for analysis of seroconversion panels. The most sensitive assay, Abbott IMx HIV-1/HIV-2 III Plus detected antibodies in all nine samples collected from four individuals during the first week after onset of symptoms of primary HIV-1 infection. Most of the assays became reactive during the second week after onset of symptoms and the least sensitive assays were reactive from the third week. The assays showed a high specificity ranging from 99.2 to 100% when used for analysis of Swedish blood donor sera, while most of the assays showed a significantly lower specificity, 91.9-99.6%, when used for testing African specimens. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 151
页数:13
相关论文
共 29 条
[1]   Most HIV-1 genetic subtypes have entered Sweden [J].
Alaeus, A ;
Leitner, T ;
Lidman, K ;
Albert, J .
AIDS, 1997, 11 (02) :199-202
[2]   Lack of screening test sensitivity during HIV-1 non-subtype B seroconversions [J].
Apetrei, C ;
LoussertAjaka, I ;
Descamps, D ;
Damond, F ;
Saragosti, S ;
BrunVezinet, F ;
Simon, F .
AIDS, 1996, 10 (14) :F57-F60
[3]   A COMPARISON OF 4 ENZYME IMMUNOASSAYS FOR THE SIMULTANEOUS DETECTION OF HIV-1-SPECIFIC AND HIV-2-SPECIFIC ANTIBODY [J].
BERRY, NJ ;
SALKER, R ;
CONTRERAS, M ;
BARBARA, JAJ ;
TEDDER, RS .
JOURNAL OF VIROLOGICAL METHODS, 1991, 34 (01) :91-100
[4]   EVALUATION OF COMMERCIAL ENZYME IMMUNOASSAYS FOR ANTI-HIV-1 USING EAST-AFRICAN SERA [J].
BREDBERGRADEN, U ;
KIANGO, J ;
MHALU, F ;
BIBERFELD, G .
AIDS, 1988, 2 (04) :281-285
[5]  
BREDBERGRADEN U, 1997, UNPUB SUBTYPE DETERM
[6]   Optimisation of a peptide-based indirect ELISA for the detection of antibody in the serum of HIV-1 seropositive patients [J].
Brown, L ;
Westby, M ;
Souberbielle, BE ;
Szawlowski, PWS ;
Kemp, G ;
Hay, P ;
Dalgleish, AG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 200 (1-2) :79-88
[7]   Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies [J].
Burgisser, P ;
Simon, F ;
Wernli, M ;
Wust, T ;
Beya, MF ;
Frei, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (03) :634-637
[8]   TIME-COURSE OF DETECTION OF VIRAL AND SEROLOGIC MARKERS PRECEDING HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 SEROCONVERSION - IMPLICATIONS FOR SCREENING OF BLOOD AND TISSUE DONORS [J].
BUSCH, MP ;
LEE, LLL ;
SATTEN, GA ;
HENRARD, DR ;
FARZADEGAN, H ;
NELSON, KE ;
READ, S ;
DODD, RY ;
PETERSEN, LR .
TRANSFUSION, 1995, 35 (02) :91-97
[9]   False negative anti-HIV-1 HIV-2 ELISAs in acute HIV-2 infection [J].
Christiansen, CB ;
Jessen, TE ;
Nielsen, C ;
StaunOlsen, P .
VOX SANGUINIS, 1996, 70 (03) :144-147
[10]   SENSITIVITY OF HIV-ANTIBODY ASSAYS DETERMINED BY SEROCONVERSION PANELS [J].
CONSTANTINE, NT ;
VANDERGROEN, G ;
BELSEY, EM ;
TAMASHIRO, H .
AIDS, 1994, 8 (12) :1715-1720