Demonstration of potential noninvasive ultrasound brain therapy through an intact skull

被引:356
作者
Hynynen, K
Jolesz, FA
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
ultrasound; brain; therapy; surgery; high intensity ultrasound; cavitation; thermal therapy;
D O I
10.1016/S0301-5629(97)00269-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Utilization of therapeutic ultrasound in the brain has been seriously limited by the commonly accepted view that these exposures would require that a piece of the skull bone be removed to allow the ultrasound beam to propagate into the brain. In this paper, the feasibility of delivering ultrasound therapy through the intact skull was studied. Sonications were performed through a piece of human skull with focused transducers at 0.248, 0.559 1.0 and 1.68 MHz. The skull attenuated and distorted the field; however, a sharp focal spot was created at frequencies of 1 MHz or lower. At the higher frequency, the focus was destroyed. To investigate the feasibility of compensating for the ultrasound field distortion caused by the bone, phased array experiments were performed. Two arrays with 64 elements, operating at 0.6 MHz and 1.58 MHz, were used in these experiments. The phase shifts caused by the skull were measured for each element of the arrays and then compensated for by phase-control circuitry. These phase corrections allowed a sharp focus to be generated at both frequencies. Finally, tissue destruction was induced by using pulsed sonication through a piece of human skull in a rabbit brain in vivo at the frequency of 0.559 MHz. In summary, the results showed that transcranial delivery of therapeutic ultrasound into the brain may be feasible. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:275 / 283
页数:9
相关论文
共 37 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]  
[Anonymous], 113 NCRP
[3]   EFFECTS OF PHYSICAL PARAMETERS ON HIGH-TEMPERATURE ULTRASOUND HYPERTHERMIA [J].
BILLARD, BE ;
HYNYNEN, K ;
ROEMER, RB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (04) :409-420
[4]   DESIGN AND EXPERIMENTAL EVALUATION OF ARM INTRACAVITARY ULTRASOUND PHASED-ARRAY SYSTEM FOR HYPERTHERMIA [J].
BUCHANAN, MT ;
HYNYNEN, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (12) :1178-1187
[5]   BIOLOGICAL EFFECTS OF SHOCK-WAVES - IN-VIVO EFFECT OF HIGH-ENERGY PULSES ON RABBIT BONE [J].
DELIUS, M ;
DRAENERT, K ;
ALDIEK, Y ;
DRAENERT, Y .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) :1219-1225
[6]   Physical characteristics and biological effects of laser-induced stress waves [J].
Doukas, AG ;
Flotte, TJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (02) :151-164
[7]   CONTROL OF THE NECROSED TISSUE VOLUME DURING NONINVASIVE ULTRASOUND SURGERY USING A 16-ELEMENT PHASED-ARRAY [J].
FAN, XB ;
HYNYNEN, K .
MEDICAL PHYSICS, 1995, 22 (03) :297-306
[8]  
FRY F J, 1977, Ultrasound in Medicine and Biology, V3, P179, DOI 10.1016/0301-5629(77)90069-2
[9]  
FRY F J, 1970, Journal of the Acoustical Society of America, V48, P1413, DOI 10.1121/1.1912301
[10]   ACOUSTICAL PROPERTIES OF HUMAN SKULL [J].
FRY, FJ ;
BARGER, JE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (05) :1576-1590