Hand-held dynamometry in persons with tetraplegia - Comparison of make- versus break-testing techniques

被引:29
作者
Burns, SP
Breuninger, A
Kaplan, C
Marin, H
机构
[1] Vet Affairs Puget Sound Hlth Care Syst, Spinal Cord Injury Serv, Seattle, WA 98108 USA
[2] Univ Washington, Dept Rehabil Med, Seattle, WA 98195 USA
[3] Univ Washington, Harborview Med Ctr, Harborview Injury Prevent & Res Ctr, Seattle, WA 98104 USA
关键词
spinal cord injuries; muscle strength; muscle spasticity; reproducibility of results;
D O I
10.1097/01.PHM.0000150790.99514.C6
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To compare make and break techniques for hand-held dynamometry in persons with tetraplegia. We compared the interrater and intrarater reliability, the relative forces, and variability between examiner techniques. Design: Two examiners with no previous hand-held dynamometry training performed hand-held dynamometry on the elbow flexors or extensors of 19 persons with upper limb weakness secondary to tetraplegia, using break and make techniques. Testing was performed in two sessions separated by 10 mins. Simultaneous recording from an electrogoniometer placed across the elbow was obtained for a subset of participants. Results: Break and make techniques both showed intraclass correlation coefficients exceeding 0.9 for interrater and intrarater reliability. The maximum expected difference for 95% of repeated measurements was 3.5 kg, with hand-held dynamometry strength values that averaged 7-11 kg. Average break/make ratios ranged from 1.38 +/- 0.29 to 1.49 +/- 0.37. The electrogoniometric data showed that the two examiners used similar testing technique, and small variations in technique were not associated with significant differences in strength recordings. Conclusion: Make and break techniques for hand-held dynamometry both show high reliability over a short intersession period when performed by inexperienced examiners on weak elbow flexors and extensors.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 26 条
[1]  
AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
[2]  
*AM SPIN INJ ASS I, 1994, REF MAN STAND NEUR F
[3]   Measurement error [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 312 (7047) :1654-1654
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BOHANNON R W, 1990, Physiotherapy Canada, V42, P247
[6]   MAKE TESTS AND BREAK TESTS OF ELBOW FLEXOR MUSCLE STRENGTH [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1988, 68 (02) :193-194
[7]   HAND-HELD MYOMETRY [J].
BOHANNON, RW .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1992, 55 (10) :982-982
[8]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[9]   Neuromuscular findings in thyroid dysfunction: a prospective clinical and electrodiagnostic study [J].
Duyff, RF ;
Van den Bosch, J ;
Laman, DM ;
van Loon, BJP ;
Linssen, WHJP .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2000, 68 (06) :750-755
[10]   Grade 4 in manual muscle testing: The problem with submaximal strength assessment [J].
Dvir, Z .
CLINICAL REHABILITATION, 1997, 11 (01) :36-41