Quantitative analysis of cocaine and its metabolites in whole blood and urine by high-performance liquid chromatography coupled with tandem mass spectrometry

被引:69
作者
Johansen, Sys Stybe [1 ]
Bhatia, Helle Merete [1 ]
机构
[1] Univ Copenhagen, Inst Forens Med, Dept Forens Chem, DK-2100 Copenhagen, Denmark
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 852卷 / 1-2期
关键词
cocaine and metabolites; forensic samples; LC/MS/MS;
D O I
10.1016/j.jchromb.2007.01.033
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Aim: In forensic toxicology it is important to have specific and sensitive analysis for quantification of illicit drugs in biological matrices. This paper describes a quantitative method for determination of cocaine and its major metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and urine by liquid chromatography coupled with tandem mass spectrometry LC/MS/MS. Method: The sample pre-treatment (0.20 g) consisted of acid precipitation, followed by centrifugation and solid phase extraction of supernatant using mixed mode sorbent columns (SPEC (R) MPI Ansys Diag. Inc.). Chromatographic separation was performed at 30 degrees C on a reverse phase Zorbax C18 column with a gradient system consisting of formic acid, water and acetonitrile. The analysis was performed by positive electrospray ionisation with a triple quadropole mass spectrometer operating in multiple reaction monitoring (MRM) mode. Two MRM transitions of each analyte were established and identification criteria were set up based on the retention time and the ion ratio. The quantification was performed using deuterated internal analytes of cocaine, benzoylecgonine and ecgonine methyl ester. The calibration curves of extracted standards were linear over a working range of 0.001-2.00 mg/kg whole blood for all analytes. The limit of quantification was 0.008 mg/kg; the interday precision (measured by relative standard deviation-%RSD) was less than 10% and the accuracy (BIAS) less than 12% for all analytes in whole blood. Urine samples were estimated semi-quantitatively at a cut-off level of 0.15 mg/kg with an interday precision of 15%. Conclusion: A liquid chromatography mass spectrometric (LC/MS/MS) method has been developed for confirmation and quantification of cocaine and its metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and semi-quantitative in urine. The method is specific and sensitive and offers thereby an excellent alternative to other methods such as GC-MS that involves derivatisation. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:338 / 344
页数:7
相关论文
共 24 条
[1]
BASELT RC, 2004, DISPOSITION TOXIC DR, V256
[2]
Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[3]
Determination of opiates and cocaine and its metabolites in biological fluids by high-performance liquid chromatography with electrospray tandem mass spectrometry [J].
Cailleux, A ;
Le Bouil, A ;
Auger, B ;
Bonsergent, G ;
Turcant, A ;
Allain, P .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1999, 23 (07) :620-624
[4]
Simultaneous screening for 238 drugs in blood by liquid chromatography-ionspray tandem mass spectrometry with multiple-reaction monitoring [J].
Gergov, M ;
Ojanperä, I ;
Vuori, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (01) :41-53
[5]
Rapid confirmation/quantitation of ecgonine methyl ester, benzoylecgonine, and cocaine in urine us on-line extraction coupled with fast HPLC and tandem mass spectrometry [J].
Jeanville, PM ;
Estapé, ES ;
Torres-Negrón, I ;
Martí, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (01) :69-75
[6]
JUFER RA, 2000, HDB ANAL SEPARATIONS, V2
[7]
Analysis of cocaine, benzoylecgonine, ecgonine methyl ester, and ecgonine by high-pressure liquid chromatography-API mass spectrometry and application to a short-term degradation study of cocaine in plasma [J].
Klingmann, A ;
Skopp, G ;
Aderjan, R .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (06) :425-430
[8]
Meeting challenges in forensic toxicology in Japan by liquid chromatography/mass spectrometry [J].
Kudo, K ;
Tsuchihashi, H ;
Ikeda, N .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :83-104
[9]
A validated liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry method for quantitation of cocaine and benzoylecgonine in human plasma [J].
Lin, SN ;
Moody, DE ;
Bigelow, GE ;
Foltz, RL .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (07) :497-503
[10]
Progress of liquid chromatography-mass spectrometry in clinical and forensic toxicology [J].
Marquet, P .