A low cost and sensitive procedure for lead screening in human whole blood with sequential injection-hydride generation-atomic fluorescence spectrometry

被引:41
作者
Wang, JH [1 ]
Yu, YL [1 ]
Du, Z [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
关键词
D O I
10.1039/b412750a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated sequential injection hydride generation(HG) atomic fluorescence spectrometric (AFS) method was developed, with the aim of screening blood lead levels for Chinese citizens, especially for children. Lead hydride was generated from acid solution, with potassium ferricyanide as an oxidizing agent, by reaction with alkaline tetrahydroborate solution. The hydride was separated from the reaction medium in a gas - liquid separator (GLS(1)) and swept directly into the atomizer. A thorough scrutiny was made of the various factors, including the modi. cation of the AFS instrument and related parameters, the various wet digestion protocols, the variables of the flow system and the reaction conditions. Under the optimized conditions the blank signal was satisfactorily minimized, giving rise to a limit of detection of 0.014 mg l(-1), defined as 3 times the blank standard deviation divided by the slope of calibration graph, and a RSD value of 0.7% (at the 2.0 mug l(-1) level, n = 11), along with a sampling frequency of 120 h(-1). The sensitivity of the procedure was found to be significantly superior to those obtained by HG-atomic emission spectrometry (AES), direct sampling electrothermal atomic absorption spectrometry (ETAAS), tungsten. lament atomizer ETAAS, and quartz tube atomizer HG-AAS; it was even lower than those by in-atomizer-trapping HG-ETAAS and comparable to ICPMS-based methods. The accuracy and practical applicability of the procedure were validated by analysing certified reference materials of frozen cattle blood GBW 09139 and GBW 09140, and further demonstrated by spiking recoveries of lead in human whole blood samples.
引用
收藏
页码:1559 / 1563
页数:5
相关论文
共 28 条
[1]  
ASTROM O, 1982, ANAL CHEM, V54, P190
[2]   Reagent injection FIA system for lead determination by hydride generation - quartz-tube atomic absorption spectrometry [J].
Baranguan, MT ;
Laborda, F ;
Castillo, JR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (01) :115-119
[3]  
BELLAMY GR, 1995, RURAL HLTH FOCUS, V6, P1
[4]   Determination of lead in calcium carbonate by flow-injection hydride generation with dc plasma atomic emission detection [J].
Brindle, ID ;
McLaughlin, R ;
Tangtreamjitmun, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1121-1129
[5]   Study of the relationships between bone lead levels and its variation with time and the cumulative blood lead index, in a repeated bone lead survey [J].
Brito, JAA ;
McNeill, FE ;
Chettle, DR ;
Webber, CE ;
Vaillancourt, C .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (03) :271-276
[6]  
Centers for Disease Control, 1991, PREV LEAD POIS YOUNG
[7]   SIMULTANEOUS REDUCTION OF ARSENIC AND LEAD TO HYDRIDES BY SODIUM TETRAHYDROBORATE(III) FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY - AN INVESTIGATION INTO THE REACTION MEDIUM [J].
CHEN, HW ;
WU, JZ ;
BRINDLE, ID .
TALANTA, 1995, 42 (03) :353-360
[8]   Determination of trace lead by hydride generation-inductively coupled plasma-mass spectrometry [J].
Chen, SY ;
Zhang, ZF ;
Yu, HM ;
Liu, WQ ;
Sun, M .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :177-188
[9]   INVESTIGATIONS FOR THE DETERMINATION OF LEAD BY IN-SITU HYDRIDE TRAPPING WITHIN A GRAPHITE ELECTROTHERMAL ATOMIZER FOR ROUTINE ANALYSIS [J].
ERBER, D ;
QUICK, L ;
WINTER, F ;
CAMMANN, K .
TALANTA, 1995, 42 (07) :927-936
[10]   Determination of manganese by graphite furnace atomic absorption spectrometry: matrix effect control by multiple linear regression model [J].
Grotti, M ;
Leardi, R ;
Gnecco, C ;
Frache, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) :845-851