Left ventricular diastolic suction with zero left atrial pressure in open-chest dogs

被引:14
作者
Ingels, NB
Daughters, GT
Nikolic, SD
DeAnda, A
Moon, MR
Bolger, AF
Komeda, M
Derby, GC
Yellin, EL
Miller, DC
机构
[1] STANFORD UNIV, SCH MED, DEPT CARDIOVASC & THORAC SURG, STANFORD, CA 94305 USA
[2] STANFORD UNIV, SCH MED, DIV CARDIOVASC MED, STANFORD, CA 94305 USA
[3] DEPT VET AFFAIRS MED CTR, CARDIAC SURG SECT, PALO ALTO, CA 94304 USA
[4] DEPT VET AFFAIRS MED CTR, CARDIOL SECT, PALO ALTO, CA 94304 USA
[5] ALBERT EINSTEIN COLL MED, BRONX, NY 10461 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1996年 / 270卷 / 04期
关键词
left ventricle; left ventricular diastolic filling; left atrium; left atrial pressure clamp;
D O I
10.1152/ajpheart.1996.270.4.H1217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated left ventricular (LV) diastolic volume changes (suction inflows) with left atrial pressure (LAP) clamped to ambient pressure in six open-chest, anesthetized dogs. The left atrium was cannulated and connected to a servo pump, and LAP was clamped to a set point near 0 mmHg for four beats by withdrawing blood. LAP averaged 5.88 +/- 1.44 mmHg before the clamp and fell to 0.74 +/- 0.61 mmHg (P < 0.0001) after the clamp. During the first clamped beat a transmitral pressure gradient of 1.0 +/- 0.6 mmHg was observed, resulting in LV filling of 2.6 +/- 1.8 ml. Subsequent beats developed suction-driven (mean negative LV pressure: -1.5 +/- 1.3 mmHg; P < 0.005 vs. zero) LV filling of 4.5 +/- 2.8 ml/beat with a peak. transmitral pressure gradient of 1.7 +/- 0.6 mmHg. These data are consistent with the hypothesis that LV suction can be an important filling mechanism under conditions in which LV end-systolic volume is reduced, e.g., reduced filling pressures, high heart rates, exercise, or increased inotropic drive.
引用
收藏
页码:H1217 / H1224
页数:8
相关论文
共 40 条
[1]   LEFT VENTRICULAR WALL MOTION DURING ISOVOLUMIC RELAXATION PERIOD [J].
ALTIERI, PI ;
WILT, SM ;
LEIGHTON, RF .
CIRCULATION, 1973, 48 (03) :499-505
[2]   SENSITIVITY OF LEFT-VENTRICULAR END-SYSTOLIC PRESSURE-VOLUME RELATION TO TYPE OF LOADING INTERVENTION IN DOGS [J].
BAAN, J ;
VANDERVELDE, ET .
CIRCULATION RESEARCH, 1988, 62 (06) :1247-1258
[3]   DIASTOLIC FILLING OF THE BEATING EXCISED HEART [J].
BLOOM, WL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1956, 187 (01) :143-144
[4]   EFFECTS OF EPINEPHRINE AND OF NOREPINEPHRINE ON CARBOHYDRATE METABOLISM IN THE RAT [J].
BLOOM, WL ;
RUSSELL, JA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1955, 183 (03) :356-364
[5]  
BLOOM WL, 1956, T ASSOC AM PHYSICIAN, V69, P200
[6]  
BLOOM WL, 1956, P SOC EXP BIOL MED, V93, P451
[7]   RADIOGRAPHIC EVALUATION OF DYNAMIC GEOMETRY OF LEFT VENTRICLE [J].
BOVE, AA .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (02) :227-&
[8]   VENTRICULAR DIASTOLIC SUCTION AT NORMAL ARTERIAL PRESSURES [J].
BRECHER, GA ;
KISSEN, AT .
CIRCULATION RESEARCH, 1958, 6 (01) :100-106
[9]   RELATION OF NEGATIVE INTRAVENTRICULAR PRESSURE TO VENTRICULAR VOLUME [J].
BRECHER, GA ;
KISSEN, AT .
CIRCULATION RESEARCH, 1957, 5 (02) :157-162
[10]   EXPERIMENTAL EVIDENCE OF VENTRICULAR DIASTOLIC SUCTION [J].
BRECHER, GA .
CIRCULATION RESEARCH, 1956, 4 (05) :513-518