Analysis of organic matter causing membrane fouling in drinking water treatment

被引:19
作者
Kaiya, Y
Itoh, Y
Takizawa, S
Fujita, K
Tagawa, T
机构
[1] Ebara Res Co Ltd, Fujisawa, Kanagawa 2518502, Japan
[2] Ebara Corp, Minato Ku, Tokyo 1088480, Japan
[3] Univ Tokyo, Dept Urban Engn, Bunkyo Ku, Tokyo 1138656, Japan
[4] Saitama Univ, Dept Environm Sci & Human Technol, Urawa, Saitama 338, Japan
[5] Nagaoka Univ Technol, Dept Environm Syst Engn, Nagaoka, Niigata 9402188, Japan
关键词
drinking water treatment; membrane fouling; molecular weight distribution; FTIR; pylolysis-GC-MS; chemical cleaning;
D O I
10.2166/wst.2000.0608
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
A study was conducted on characteristics of membrane-fouling matter and chemical cleaning of fouled membranes. The membranes were those used for the filtration of raw water taken from the Lake Kitaura, Ibaraki, Japan. Analysis of the molecular weight distribution of extracted foulants by ultrafilters showed that 23% of organic matter was in the fraction exceeding a molecular weight of 100,000 daltons and 33% between 10,000 to 100,000 daltons. Analysis by gel permeation chromatography (GPC) revealed a void peak and five peaks at a molecular weight of less than 6,000 daltons. Assessment by Fourier transform infrared spectroscopy (FTIR) and pyrolysis gas chromatography mass spectrometry (Py-GC-MS) revealed that organic fouling matter contained polysaccharides, proteins, amino sugars and aromatic compounds that constitute humic substances. A comparison of the apparent molecular weight distribution and the FTIR spectra of both the raw water and fouled membrane extracts revealed the attachment of membrane-fouling matter nonexistent in the raw water, which was considered to be extracellular organic matter. Chemical cleaning of fouled membranes suggested that sodium hypochlorite and hydrogen peroxide were effective for the recovery of membrane permeability. In most of the experiments, the higher the cleaning temperature is between 5 degrees C and 40 degrees C, the more effective the chemical cleaning. However, chemical cleaning by a mixture of 1%-NaOCl and 4%-NaOH showed a comparable cleaning efficiency at 5 degrees C as chemical cleaning at 40 degrees% after two hours.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 5 条
[1]
Irwin W.J., 1982, ANAL PYROLYSIS
[2]
Kaiya Y, 1996, DESALINATION, V106, P71, DOI 10.1016/0011-9164(96)00094-X
[3]
KAIYA Y, 1996, P 7 WORLD FILT C, P526
[4]
MALLEVIALLE J, 1989, ACS SYM SER, V219, P749
[5]
Control and modeling of membrane fouling due to microorganism growth by UV pretreatment [J].
Otaki, M ;
Takizawa, S ;
Ohgaki, S .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (4-5) :405-412