Percutaneous transthoracic needle biopsy of the lung: Review of 612 lesions

被引:78
作者
Swischuk, JL
Castaneda, F
Patel, JC
Li, RZ
Fraser, KW
Brady, TM
Bertino, RE
机构
[1] Univ Illinois, Coll Med, Dept Radiol, Peoria, IL 61637 USA
[2] Univ Illinois, Coll Med, Dept Pathol, Peoria, IL 61637 USA
关键词
fine needle aspiration; lung; biopsy; pneumothorax;
D O I
10.1016/S1051-0443(98)70279-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The results and complications of 651 pulmonary fine-needle aspiration biopsies (FNABs) were reviewed. The number of needle passes and needle size were correlated to pneumothorax and chest tube placement rates. MATERIALS AND METHODS: FNAB of the lung was performed on 651 occasions in 612 patients with 18- to 22-gauge Franseen needles. Diagnostic rates were calculated, The number of needle passes performed and needle size used were evaluated for their association with pneumothorax and subsequent chest tube placement. RESULTS: Diagnostic accuracy was 94% with sensitivity for malignancy of 95%. Positive and negative predictive values were 99.5% and 90%, respectively, Pneumothorax occurred in 26.9% of patients with 9.2% requiring chest tube placement. Increasing numbers of needle passes and larger needle sizes did not increase the rates of pneumothorax or chest tube placement. CONCLUSIONS: FNAB of the lung has excellent diagnostic rates and remains the procedure of choice for diagnosing pulmonary lesions. This large study contradicts perceptions that pneumothorax and chest tube placement rates decrease with thinner needles and fewer passes.
引用
收藏
页码:347 / 352
页数:6
相关论文
共 30 条
[1]   VALUE OF HAVING A CYTOPATHOLOGIST PRESENT DURING PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY OF LUNG - REPORT OF 55 CANCER-PATIENTS AND METAANALYSIS OF THE LITERATURE [J].
AUSTIN, JHM ;
COHEN, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :175-177
[2]  
BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
[3]   THORACIC NEEDLE-BIOPSY - IMPROVED RESULTS UTILIZING A TEAM-APPROACH [J].
CONCES, DJ ;
SCHWENK, GR ;
DOERING, PR ;
GLANT, MD .
CHEST, 1987, 91 (06) :813-816
[4]   POSTBIOPSY PNEUMOTHORAX - ESTIMATING THE RISK BY CHEST RADIOGRAPHY AND PULMONARY-FUNCTION TESTS [J].
FISH, GD ;
STANLEY, JH ;
MILLER, KS ;
SCHABEL, SI ;
SUTHERLAND, SE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (01) :71-74
[5]   INTEGRATION OF TRANSBRONCHIAL AND PERCUTANEOUS APPROACH IN THE DIAGNOSIS OF PERIPHERAL PULMONARY NODULES OR MASSES - EXPERIENCE WITH 1,027 CONSECUTIVE CASES [J].
GASPARINI, S ;
FERRETTI, M ;
SECCHI, EB ;
BALDELLI, S ;
ZUCCATOSTA, L ;
GUSELLA, P .
CHEST, 1995, 108 (01) :131-137
[6]   THIN-NEEDLE ASPIRATION BIOPSY - METHODS OF INCREASING THE ACCURACY OF A NEGATIVE PREDICTION [J].
GOBIEN, RP ;
VALICENTI, JF ;
PARIS, BS ;
DANIELL, C .
RADIOLOGY, 1982, 145 (03) :603-605
[7]   Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung [J].
Kazerooni, EA ;
Lim, FT ;
Mikhail, A ;
Martinez, FJ .
RADIOLOGY, 1996, 198 (02) :371-375
[8]   TRANS-THORACIC NEEDLE ASPIRATION BIOPSY OF BENIGN AND MALIGNANT LUNG LESIONS [J].
KHOURI, NF ;
STITIK, FP ;
EROZAN, YS ;
GUPTA, PK ;
KIM, WS ;
SCOTT, WW ;
HAMPER, UM ;
MANN, RB ;
EGGLESTON, JC ;
BAKER, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (02) :281-288
[9]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[10]   ASPIRATION BIOPSIES OF CHEST LESIONS [J].
LALLI, AF ;
MCCORMACK, LJ ;
ZELCH, M ;
REICH, NE ;
BELOVICH, D .
RADIOLOGY, 1978, 127 (01) :35-40