A simple method for suppression of resonance oscillation in PWM current source converter

被引:35
作者
Neba, Y [1 ]
机构
[1] Fukuoka Univ, Fac Engn, Dept Elect Engn, Fukuoka 8140180, Japan
关键词
current source converter; pulse-width modulation (PWM); resonance oscillation; single-phase; three-phase;
D O I
10.1109/TPEL.2004.839822
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with a suppression method for the resonance oscillation in the ac side of a pulse-width modulation (PWM) current source converter. The converter is operated with the PWM switching pattern which is generated by the full digital control of computer software. The resonance current, caused by the LC low pass filter at the step change of the pattern, can be effectively suppressed by one pulse control of the pattern. The proposed method does not need to have the feedback loop of the current/voltage and does not offer the switching stress of the devices. The switching timing of the control is determined by pre-calculation of the off-line in consideration of the circuit constants. The experimental and the simulated results in the single-phase and the three-phase PWM converters are given, compared with those without the control, and show good response of the supply current.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 16 条