Robotic total knee arthroplasty - The accuracy of CT-based component placement

被引:63
作者
Decking, J [1 ]
Theis, C
Achenbach, T
Roth, E
Nafe, B
Eckardt, A
机构
[1] Univ Mainz, Dept Orthopaed Surg, D-6500 Mainz, Germany
[2] Univ Mainz, Dept Radiol, D-6500 Mainz, Germany
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2004年 / 75卷 / 05期
关键词
D O I
10.1080/00016470410001448
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Accurate alignment of the components in total knee arthroplasty is important. By use of postoperative CT controls, we studied the ability of a robotic effector to accurately place and align total knee arthroplasty (TKA) components according to a purely CT-based preoperative plan. Patients and methods Robotic TKA was performed in 13 patients (6 men) with primary gonarthrosis. Locator screws were placed into femur and tibia under spinal anesthesia. A CT-scan including the femoral head, knee and ankle was performed. In the preoperative planning software, virtual components were positioned into the CT volume. In a second operation, the robot milled femur and tibia with a high-speed milling too] according to the preoperative plan. On the 10th day, CT controls were performed following the same protocol as preoperatively. Results The mean deviation of the postoperative from the preoperatively planned mechanical axis was 0.2degrees (95% CI: -0.1degrees to 0.5degrees). The accuracy of angular component placement in frontal, sagittal and transverse planes was within +/- 1.2degrees, and the accuracy of linear component placement in mediolateral, dorsoventral and caudocranial directions was within +/- 1.1 mm. Interpretation Robotic TKA allows placement of components with unparalleled accuracy, but further development is mandatory to integrate soft-tissue balancing into the procedure and make it faster, easier and cheaper.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 24 条
[1]
Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
[2]
Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[3]
Improving accuracy of bone resections using robotics tool holder and a high speed milling cutting tool [J].
Fadda, M ;
Marcacci, M ;
Toksvig-Larsen, S ;
Wang, T ;
Meneghello, R .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1998, 22 (06) :280-284
[4]
THE INFLUENCE OF TIBIAL-PATELLOFEMORAL LOCATION ON FUNCTION OF THE KNEE IN PATIENTS WITH THE POSTERIOR STABILIZED CONDYLAR KNEE PROSTHESIS [J].
FIGGIE, HE ;
GOLDBERG, VM ;
HEIPLE, KG ;
MOLLER, HS ;
GORDON, NH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1035-1040
[5]
HOFMANN AA, 1991, CLIN ORTHOP RELAT R, P63
[6]
COMPARISON OF 4 MODELS OF TOTAL KNEE-REPLACEMENT PROSTHESES [J].
INSALL, JN ;
RANAWAT, CS ;
AGLIETTI, P ;
SHINE, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (06) :754-765
[7]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[8]
Jenny J Y, 2001, Comput Aided Surg, V6, P217, DOI 10.1002/igs.10006.abs
[9]
Instrumentation pitfalls - You just can't go on autopilot! [J].
Laskin, RS .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :18-22
[10]
Navigation in knee arthroplasty - Preliminary clinical experience and prospective comparative study in comparison with conventional technique [J].
Mielke, RK ;
Clemens, U ;
Lens, JH ;
Kershally, S .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (02) :109-116