Determination of a series of quinolone antibiotic using liquid chromatography-mass-spectrometry

被引:20
作者
Ballesteros, O
Sanz-Nebot, V
Navalón, A
Vílchez, JL
Barbosa, J
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
[2] Univ Granada, Dept Analyt Chem, E-18071 Granada, Spain
关键词
column liquid chromatography; mass spectrometry detection; mobile phase optimization; quinolones in animal products;
D O I
10.1365/s10337-004-0277-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this work was to develop a method of characterization and determination of ten quinolones by liquid chromatography (LC) coupled to pneumatically assisted electrospray ionization (ESI) mass spectrometry (MS). For this purpose, the operational parameters of LC-ESI-MS were optimized in order to obtain suitable separations and high sensitivity of the greatest number of quinolones. In the established method, the mobile phase is composed of acetonitrile and acetate-formiate buffer at pH 2.5, with an initial composition of 18:82 by volume of acetonitrile-water, and using a linear gradient elution. Quality parameters were determined and satisfactory results were obtained. Likewise, the method detection limit was about 10-ng(.)mL(-1) for most of the quinolones studied employing selected-ion monitoring mode and using an internal standard. The method was specific and reproducible. Thus, the proposed methodology can be applied for control of these compounds in animal products commonly consumed in the human diet.
引用
收藏
页码:543 / 550
页数:8
相关论文
共 27 条
[1]   Residues of antimicrobial drugs and feed additives in animal products:: regulatory aspects [J].
Anadón, A ;
Martínez-Larrañaga, MR .
LIVESTOCK PRODUCTION SCIENCE, 1999, 59 (2-3) :183-198
[2]   Optimization of the composition and pH of the mobile phase used for separation and determination of a series of quinolone antibacterials regulated by the European Union [J].
Ballesteros, O ;
Toro, I ;
Sanz-Nebot, V ;
Navalón, A ;
Vílchez, JL ;
Barbosa, J .
CHROMATOGRAPHIA, 2002, 56 (7-8) :413-421
[3]   Solvatochromic parameter values and pH in acetonitrile-water mixtures - Optimization of mobile phase for the separation of peptides by high-performance liquid chromatography [J].
Barbosa, J ;
SanzNebot, V ;
Toro, I .
JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (02) :249-260
[4]   Solvatochromic parameter values and pH in aqueous-organic mixtures used in liquid chromatography - Prediction of retention of a series of quinolones [J].
Barbosa, J ;
Berges, R ;
SanzNebot, V .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :27-36
[5]   Prediction of the chromatographic behaviour for a series of diuretic compounds [J].
Barbosa, J ;
Bergés, R ;
Sanz-Nebot, V .
CHROMATOGRAPHIA, 2000, 51 (7-8) :417-427
[6]   Retention behaviour of peptides, quinolones, diuretics and peptide hormones in liquid chromatography -: Influence of ionic strength and pH on chromatographic retention [J].
Barbosa, J ;
Toro, I ;
Bergés, R ;
Sanz-Nebot, V .
JOURNAL OF CHROMATOGRAPHY A, 2001, 915 (1-2) :85-96
[7]   THERMODYNAMIC ORIGIN OF THE SUB-NERNSTIAN RESPONSE OF GLASS ELECTRODES [J].
BAUCKE, FGK .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4519-4524
[8]   Modelling retention in liquid chromatography as a function of solvent composition and pH of the mobile phase [J].
Bergés, R ;
Sanz-Nebot, V ;
Barbosa, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :27-39
[9]  
*COMM EUR COMM, 1990, DIAR OF COM EUR DOCE, V118, P64
[10]  
*COMM EUR COMM, 1990, DIAR OF COM EUR DO L, V224, P991