Photo-cured ammonium and hydrogen ion selective coated-wire electrodes used simultaneously in a portable battery-powered flow injection analyzer

被引:14
作者
Alexander, PW
Dimitrakopoulos, T
Hibbert, DB
机构
[1] Univ Tasmania, Dept Phys Sci, Launceston, Tas 7250, Australia
[2] Univ New S Wales, Dept Analyt Chem, Sydney, NSW 2052, Australia
关键词
photo-cured membranes; ammonium and pH coated wire electrodes; flow injection potentiometry;
D O I
10.1002/elan.1140091706
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nonactin and N,N-dioctadecylmethylamine ionophores, each in an epoxydiacrylate polymer, were photo-cured on silver wires (0.8 mm i.d.) and evaluated as ammonium and hydrogen (pH) coated wire electrodes. The photo-cured membranes prepared in this study exhibited excellent adhesion to the metal substrate and improved mechanical strength compared to PVC based membranes. The ammonium electrode exhibited a Nernstian response over a concentration range between 0.01 mM and 100 mM with a detection limit of 0.0005 mM. The ammonium electrode exhibited improved selectivity against most common interfering ions, including potassium compared to previous studies. The hydrogen selective electrode exhibited a near-Nernstian slope of 55.9 +/- 0.8 mV change/log a((H+)) between pH 4.0 and pH 11.0 in the steady-state mode. The ammonium and pH sensors each responded quickly reaching 90% of steady-state value in<5s, making these coated wire sensors ideal for flow injection potentiometry measurements. In the FIP mode, both the photo-cured ammonium and pH electrodes exhibited near-Nernstian responses of 49.2 +/- 1.0 mV change/activity decade and 50.2 +/- 0.4 mV change/log a((H+)), respectively, over a similar concentration range as in the steady-state mode. The photo-cured ammonium and pH electrodes were used simultaneously in the analysis of hydroponic nutrient solutions and waste water samples obtained from a local greenhouse grower in the dow injection potentiometric mode.
引用
收藏
页码:1331 / 1336
页数:6
相关论文
共 29 条
[1]   A photo-cured coated wire potassium ion-selective electrode for use in flow injection potentiometry [J].
Alexander, PW ;
Dimitrakopoulos, T ;
Hibbert, DB .
ELECTROANALYSIS, 1997, 9 (11) :813-817
[2]  
Alexander PW, 1996, FIELD ANAL CHEM TECH, V1, P31
[3]  
ALEXANDER PW, 1997, IN PRESS TALANTA
[4]  
BATES RG, 1973, DETERMINATION PH THE, P330
[5]   ION SENSOR WITH PHOTOCURABLE POLYURETHANE POLYMER MEMBRANE [J].
BRATOV, A ;
ABRAMOVA, N ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S ;
BARTROLI, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1994, 141 (09) :L111-L112
[6]   PHOTOCURABLE POLYMER MATRICES FOR POTASSIUM-SENSITIVE ION-SELECTIVE ELECTRODE MEMBRANES [J].
BRATOV, A ;
ABRAMOVA, N ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S ;
BARTROLI, J .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3589-3595
[7]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .2. A CALCIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1985, 177 :239-242
[8]   PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .3. A POTASSIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1988, 204 (1-2) :329-332
[9]   PHOTOCURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES [J].
CATTRALL, RW ;
ILES, PJ ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :403-406
[10]  
CATTRALL RW, 1984, ION SEL ELECTRODE R, V6, P125