Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound

被引:35
作者
Degertekin, M
Regar, E
Tanabe, K
Lemos, P
Lee, CH
Smits, P
de Feyter, P
Bruining, N
Sousa, E
Abizaid, A
Ligthart, J
Serruys, PW
机构
[1] Erasmus Med Ctr, Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[2] Inst Dante Pazzanese Cardiol, Sao Paulo, Brazil
关键词
D O I
10.1016/S0002-9149(03)00146-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluates the response of the coronary vessel wall to implantation of the sirolimus-eluting stent (SES), Bx-VELOCITY, by using serial intravascular ultrasound. SESs have a major impact on the inhibition of in-stent neointimal hyperplasia. However, changes in the vessel wall and behind stent struts in animal models and humans have not been evaluated after SES implantation. Thirty-four patients who received a SES (n = 24) or a Bx-VELOCITY bare stent (BS) (n = 10) for single de novo coronary lesions and had serial motorized pullback 3-dimensional intravascular ultrasound were included. Stent, lumen, and vessel volumes were similar in the 2 groups at baseline. At follow-up, significantly larger lumen and lower neointimal hyperplasia volumes (0.7 vs 33 mm(3), p = 0.001) were seen in the SES group compared with the BS group. There was no significant difference between SES and BS in either the vessel volume (+2.4% vs +0.7%, p = NS),or the plaque behind stent volume change (+3.4% vs +2.5%, p = NS) from after the procedure to late follow-up. The stent edges also showed no significant difference between postprocedural and follow-up measurements, either in patients receiving SESs or BSs. No stented or edge segment required redilatation in the SES group, whereas 2 patients underwent repeat percutaneous coronary angioplasty in the BS group. In the SES group, I patient (4%) showed late acquired incomplete stent opposition. Thus, the SES is effective in inhibiting neointimal hyperplasia without affecting vessel volume and plaque behind the stent. (C) 2003 by Excerpta Medica, Inc.
引用
收藏
页码:1046 / 1050
页数:5
相关论文
共 13 条
  • [1] Edge restenosis after implantation of high activity 32P radioactive β-emitting stents
    Albiero, R
    Nishida, T
    Adamian, M
    Amato, A
    Vaghetti, M
    Corvaja, N
    Di Mario, C
    Colombo, A
    [J]. CIRCULATION, 2000, 101 (21) : 2454 - 2457
  • [2] Late coronary occlusion after intracoronary brachytherapy
    Costa, MA
    Sabaté, M
    van der Giessen, WJ
    Kay, IP
    Cervinka, P
    Ligthart, JMR
    Serrano, P
    Coen, VLMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 1999, 100 (08) : 789 - 792
  • [3] RAPAMYCIN INHIBITS ARTERIAL INTIMAL THICKENING CAUSED BY BOTH ALLOIMMUNE AND MECHANICAL INJURY - ITS EFFECT ON CELLULAR, GROWTH-FACTOR, AND CYTOKINE RESPONSES IN INJURED VESSELS
    GREGORY, CR
    HUIE, P
    BILLINGHAM, ME
    MORRIS, RE
    [J]. TRANSPLANTATION, 1993, 55 (06) : 1409 - 1418
  • [4] A novel approach to quantitative analysis of intra vascular ultrasound images
    Hamers, R
    Bruining, N
    Knook, M
    Sabate, M
    Roelandt, JRTC
    [J]. COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 589 - 592
  • [5] Novel drug-delivery stent - Intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system
    Honda, Y
    Grube, E
    de la Fuente, LM
    Yock, PG
    Stertzer, SH
    Fitzgerald, PJ
    [J]. CIRCULATION, 2001, 104 (04) : 380 - 383
  • [6] Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation
    Kay, IP
    Sabaté, M
    Costa, MA
    Kozuma, K
    Albertal, M
    van der Giessen, WJ
    Wardeh, AJ
    Ligthart, JMR
    Coen, VMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 2000, 102 (12) : 1434 - 1439
  • [7] Three-dimensional intravascular ultrasound assessment of noninjured edges of β-irradiated coronary segments
    Kozuma, K
    Costa, MA
    Sabaté, M
    Kay, IP
    Marijnissen, JPA
    Coen, VLMA
    Serrano, P
    Ligthart, JMR
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 2000, 102 (13) : 1484 - 1489
  • [8] A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.
    Morice, M
    Serruys, PW
    Sousa, JE
    Fajadet, J
    Hayashi, EB
    Perin, M
    Colombo, A
    Schuler, G
    Barragan, P
    Guagliumi, G
    Molnar, F
    Falotico, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) : 1773 - 1780
  • [9] Morino Y, 2001, J Invasive Cardiol, V13, P409
  • [10] Mudra H, 1997, CIRCULATION, V95, P363