Fluorescence-intensity multiplexing: Simultaneous seven-marker, two-color immunophenotyping using flow cytometry

被引:27
作者
Bradford, JA
Buller, G
Suter, M
Ignatius, M
Beechem, JM
机构
[1] Mol Probes Inc, Flow Cytometry Dept, Eugene, OR 97402 USA
[2] Oregon Med Labs, Eugene, OR USA
来源
CYTOMETRY PART A | 2004年 / 61A卷 / 02期
关键词
fluorescence-intensity multiplexing; molar ratio; Zenon reagent labeling; fluorophore; multivariate pattern;
D O I
10.1002/cyto.a.20037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Conventional immuno-based multiparameter flow cytometric analysis has been limited by the requirement of a dedicated detection channel for each antibody-fluorophore set. To address the need to resolve multiple biological targets simultaneously, flow cytometers with as many as 10 - 15 detection channels have been developed. In this study, a new Zenon immunolabeling technology is developed that allows for multiple antigen detection per detection channel using a single fluorophore, through a unique method of fluorescence-intensity multiplexing. By varying the Zenon labeling reagent-to-antibody molar ratio, the fluorescence intensity of the antibody-labeled cellular targets can be used as a unique identifier. Although demonstrated in the present study with lymphocyte immunophenotyping, this approach is broadly applicable for any immuno-based multiplexed flow cytomety assay. Methods: Lymphocyte immunophenotyping of 38 clinical blood specimens using CD3, CD4, CD8, CD16, CD56, CD19, and CD20 antibodies was performed using conventional flow cytometric analysis and fluorescence-intensity multiplexing analysis. Conventional analysis measures a single antibody-fluorophore per photomultiplier tube (PMT). Fluorescence-intensity multiplex analysis simultaneously measures seven markers with two PMTs, using Zenon labeling reagent-antibody complexes in a single tube: CID19, CD4, CD8, and CD 16 antibodies labeled with Zenon Alexa Fluor ((R))488 Mouse IgG(1) labeling reagent and CD56, CD3, and CD20 antibodies labeled with Zenon R-Phycoerythrin (R-PE) Mouse IgG(1) or IgG(2b) labeling reagents. Results: The lymphocyte immunophenotyping results from fluorescence-intensity multiplexing using Zenon labeling reagents in a single tube were comparable to results from conventional flow cytometric analysis. Conclusions: Simultaneous evaluation of multiple antigens using a single fluorophore can be performed using antibodies labeled with varying ratios of a Zenon labeling reagent. Labeling two sets of antibodies with different Zenon labeling reagents can generate characteristic and distinguishable multivariate patterns. Combining multiple antibodies and fluorescent labels with fluorescence intensity multiplexing enables the resolution of more cellular targets than detection-channels, allowing sophisticated multiparameter flow cytometric studies to be performed on less complex 2- or 3-detection-channel flow cytometers. For typical biological samples, approximately 2-4 cellular targets per detection channel can be resolved using this technique. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:142 / 152
页数:11
相关论文
共 23 条
[1]  
Alamo AL, 2000, CYTOMETRY, V42, P363, DOI 10.1002/1097-0320(20001215)42:6<363::AID-CYTO1003>3.0.CO
[2]  
2-E
[3]  
[Anonymous], MMWR
[4]   Selection of lymphocyte gating protocol has an impact on the level of reliability of T-cell subsets in aging specimens [J].
Bergeron, M ;
Nicholson, JKA ;
Phaneuf, S ;
Ding, T ;
Soucy, N ;
Badley, AD ;
Foss, NCH ;
Mandy, F .
CYTOMETRY, 2002, 50 (02) :53-61
[5]   SIMULTANEOUS IDENTIFICATION OF 8 LEUKOCYTE SUBSETS OF HUMAN PERIPHERAL-BLOOD USING 3-COLOR IMMUNOFLUORESCENCE FLOW CYTOMETRIC ANALYSIS [J].
CARAYON, P ;
BORD, A ;
RAYMOND, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 138 (02) :257-264
[6]  
COON JS, 1991, DIAGNOSTIC FLOW CYTO, P55
[7]   Changes in peripheral blood double-negative T-lymphocyte (CD3+ CD4- CD8-) populations associated with acute cellular rejection after liver transplantation [J].
Crosbie, OM ;
Costello, PJ ;
O'Farrelly, C ;
Hegarty, JE .
LIVER TRANSPLANTATION AND SURGERY, 1998, 4 (02) :141-145
[8]   11-color, 13-parameter flow cytometry: Identification of human naive T cells by phenotype, function, and T-cell receptor diversity [J].
De Rosa, SC ;
Herzenberg, LA ;
Herzenberg, LA ;
Roederer, M .
NATURE MEDICINE, 2001, 7 (02) :245-248
[9]   Beyond six colors: A new era in flow cytometry [J].
De Rosa, Stephen C. ;
Brenchley, Jason M. ;
Roederer, Mario .
NATURE MEDICINE, 2003, 9 (01) :112-117
[10]   IMPROVED FLOW CYTOMETRIC ANALYSIS OF LEUKOCYTE SUBSETS - SIMULTANEOUS IDENTIFICATION OF 5 CELL SUBSETS USING 2-COLOR IMMUNOFLUORESCENCE [J].
HORAN, PK ;
SLEZAK, SE ;
POSTE, G .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (21) :8361-8365