Photonic crystal aqueous metal cation sensing materials

被引:139
作者
Asher, SA [1 ]
Sharma, AC [1 ]
Goponenko, AV [1 ]
Ward, MM [1 ]
机构
[1] Univ Pittsburgh, Chevron Sci Ctr, Dept Chem, Pittsburgh, PA 15260 USA
关键词
D O I
10.1021/ac026328n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a polymerized crystalline colloidal array photonic material that senses metal cations in water at low concentrations (PCCACS). Metal cations such as Cu2+, Co2+, Ni2+, and Zn2+ bind to 8-hydroxyquinoline groups covalently attached to the PCCACS. At low metal concentrations (<muM), the cations form bisliganded complexes with two 8-hydroxyquinolines that cross-link the hydrogel and cause it to shrink, which blue shifts the photonic crystal diffraction. These bisliganded cross-links break at higher cation concentrations due to the formation of monoliganded cation complexes. This red shifts the diffraction. We have extended hydrogel volume phase transition theory in order to quantitatively model the diffraction dependence upon metal concentration. These materials can be used as a dosimeter to sense extremely low metal cation concentrations or as a sensor material for concentrations greater than 1 muM. Metal cation concentrations can be determined visually from the color of the diffracted light or can be determined by reflectance measurements using a spectrophotometer. This sensing material could be used in the field to visually determine metal cation concentrations in drinking water. A color chart would be used to relate the diffracted color to the metal cation concentration.
引用
收藏
页码:1676 / 1683
页数:8
相关论文
共 28 条
  • [1] ALEXEEV VL, UNPUB J AM CHEM SOC
  • [2] Asher S.A., 1986, SPECTROSCOPY, V1, P26
  • [3] SELF-ASSEMBLY MOTIF FOR CREATING SUBMICRON PERIODIC MATERIALS - POLYMERIZED CRYSTALLINE COLLOIDAL ARRAYS
    ASHER, SA
    HOLTZ, J
    LIU, L
    WU, ZJ
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (11) : 4997 - 4998
  • [4] ASHER SA, UNPUB J AM CHEM SOC
  • [5] ASHER SA, 1909, MRS BULL, P44
  • [6] The new wave of ion-selective electrodes.
    Bakker, E
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (15) : 420A - 426A
  • [7] Bis-8-hydroxyquinoline-armed diazatrithia-15-crown-5 and diazatrithia-16-crown-5 ligands: Possible fluorophoric metal ion sensors
    Bronson, RT
    Bradshaw, JS
    Savage, PB
    Fuangswasdi, S
    Lee, SC
    Krakowiak, KE
    Izatt, RM
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 2001, 66 (14) : 4752 - 4758
  • [8] CHARACTERIZATION OF OPTICAL DIFFRACTION AND CRYSTAL-STRUCTURE IN MONODISPERSE POLYSTYRENE COLLOIDS
    CARLSON, RJ
    ASHER, SA
    [J]. APPLIED SPECTROSCOPY, 1984, 38 (03) : 297 - 304
  • [9] CHEMICAL COMMUNICATION IN WATER USING FLUORESCENT CHEMOSENSORS
    CZARNIK, AW
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 1994, 27 (10) : 302 - 308
  • [10] Dean J.A, 1973, Lange's Handbook of Chemistry