Source of bacterial shedding in laminar flow theatres

被引:49
作者
Owers, KL [1 ]
James, E [1 ]
Bannister, GC [1 ]
机构
[1] Southmead Gen Hosp, N Bristol NHS Trust, Bristol, Avon, England
关键词
infection; arthroplasty; shedding; theatre clothing;
D O I
10.1016/j.jhin.2004.06.028
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
In a previous unpublished observation, unacceptably high bacterial, counts, presumably due to shedding episodes, occurred in two of 56 (3.57%) slit-air samples during arthroplasty surgery in a laminar flow operating theatre. The isolates matched those cultured from swab samples taken from the skin of one of the surgeons's foreheads on each of the two occasions. These findings occurred despite scrub staff wearing standard occlusive gowns, hats and masks with visors. In order to localize the potential source of such shedding more accurately, 20 members of theatre staff underwent anonymous microbiological swabbing from the facial areas not covered by theatre clothing, namely their foreheads, eyebrows and ears. These swabs were cultured and the growths were compared statistically. Significantly more colonies were cultured from swabs taken from the theatre staff's ears (P = 0.047, Freidman's test) compared with the other two facial areas studied. These data support the use of exhaust helmets in arthroplasty surgery, or at least mandatory coverage of the ears with theatre hats for scrub staff. (C) 2004 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:230 / 232
页数:3
相关论文
共 6 条
[1]   Effect of jewellery on surface bacterial counts of operating theatres [J].
Bartlett, GE ;
Pollard, TCB ;
Bowker, KE ;
Bannister, GC .
JOURNAL OF HOSPITAL INFECTION, 2002, 52 (01) :68-70
[2]   Clothing in laminar-flow operating theatres [J].
Hubble, MJ ;
Weale, AE ;
Perez, JV ;
Bowker, KE ;
MacGowan, AP ;
Bannister, GC .
JOURNAL OF HOSPITAL INFECTION, 1996, 32 (01) :1-7
[3]   Direct measurement of bacterial penetration through surgical gowns: a new method [J].
Lankester, BJA ;
Bartlett, GE ;
Garneti, N ;
Blom, AW ;
Bowker, KE ;
Bannister, GC .
JOURNAL OF HOSPITAL INFECTION, 2002, 50 (04) :281-285
[4]   AIR, ANTIBIOTICS AND SEPSIS IN REPLACEMENT JOINTS [J].
LIDWELL, OM .
JOURNAL OF HOSPITAL INFECTION, 1988, 11 :18-40
[5]   The effect of facial hair and sex on the dispersal of bacteria below a masked subject [J].
McLure, HA ;
Mannam, M ;
Talboys, CA ;
Azadian, BS ;
Yentis, SM .
ANAESTHESIA, 2000, 55 (02) :173-176
[6]   INFECTION AND INTERPOSITION BETWEEN ULTRACLEAN AIR SOURCE AND WOUND [J].
TAYLOR, GJS ;
BANNISTER, GC .