Simulating coronary arteries in x-ray angiograms

被引:15
作者
Morioka, CA
Abbey, CK
Eckstein, M
Close, RA
Whiting, JS
LeFree, M
机构
[1] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[2] Quinton Instruments, Bothell, WA 98021 USA
关键词
quantitative coronary angiography; modeling; x-ray phantom; edge detection;
D O I
10.1118/1.1308280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Clinical validation of quantitative coronary angiography (QCA) algorithms is difficult due to the lack of a simple alternative method for accurately measuring in vivo vessel dimensions. We address this problem by embedding simulated coronary artery segments with known geometry in clinical angiograms. Our vessel model accounts for the profile of the vessel, x-ray attenuation in the original background, and noise in the imaging system. We have compared diameter measurements of our computer simulated arteries with measurements of an x-ray Telescopic-Shaped Phantom (XTSP) with the same diameters. The results show that for both uniform and anthropomorphic backgrounds there is good agreement in the measured diameters of XTSP compared to the simulated arteries (Pearson's correlation coefficient 0.99). In addition, the difference in accuracy and precision of the true diameter measures compared to the XTSP and simulated artery diameters was small (mean absolute error across all diameters was less than or equal to0.11 mm +/-0.09 mm). (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01610-2].
引用
收藏
页码:2438 / 2444
页数:7
相关论文
共 16 条
  • [1] VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS
    DEROUEN, TA
    MURRAY, JA
    OWEN, W
    [J]. CIRCULATION, 1977, 55 (02) : 324 - 328
  • [2] AUTOMATED-ANALYSIS OF CORONARY ARTERIAL MORPHOLOGY IN CINEANGIOGRAMS - GEOMETRIC AND PHYSIOLOGIC VALIDATION IN HUMANS
    FLEAGLE, SR
    JOHNSON, MR
    WILBRICHT, CJ
    SKORTON, DJ
    WILSON, RF
    WHITE, CW
    MARCUS, ML
    COLLINS, SM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (04) : 387 - 400
  • [3] HARRINGTON DM, 1993, CATHET CARDIOVASC DI, V29, P314
  • [4] HASSE J, 1993, CATHET CARDIVOASC DI, V30, P104
  • [5] JUDY P F, 1976, Medical Physics (Woodbury), V3, P233, DOI 10.1118/1.594283
  • [6] KIRKEEIDE RL, 1982, COMPUT CARDIOL, P215
  • [7] LEFREE MT, P SPIE, V626
  • [8] SCATTER ESTIMATION FOR A DIGITAL RADIOGRAPHIC SYSTEM USING CONVOLUTION FILTERING
    LOVE, LA
    KRUGER, RA
    [J]. MEDICAL PHYSICS, 1987, 14 (02) : 178 - 185
  • [9] AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD
    MANCINI, GBJ
    SIMON, SB
    MCGILLEM, MJ
    LEFREE, MT
    FRIEDMAN, HZ
    VOGEL, RA
    [J]. CIRCULATION, 1987, 75 (02) : 452 - 460
  • [10] Measuring the accuracy and precision of quantitative coronary angiography using a digitally simulated test phantom
    Morioka, CA
    Whiting, JS
    LeFree, M
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 1266 - 1274