On-chip generation of microbubbles as a practical technology for manufacturing contrast agents for ultrasonic imaging

被引:231
作者
Hettiarachchi, Kanaka
Talu, Esra
Longo, Marjorie L.
Dayton, Paul A.
Lee, Abraham P. [1 ]
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Mech & Aerosp Engn, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
关键词
D O I
10.1039/b701481n
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a new manufacturing method to generate monodisperse microbubble contrast agents with polydispersity index (sigma) values of < 2% through microfluidic flow-focusing. Micron-sized lipid shell-based perfluorocarbon (PFC) gas microbubbles for use as ultrasound contrast agents were produced using this method. The poly( dimethylsiloxane) (PDMS)-based devices feature expanding nozzle geometry with a 7 mm orifice width, and are robust enough for consistent production of microbubbles with runtimes lasting several hours. With high-speed imaging, we characterized relationships between channel geometry, liquid flow rate Q, and gas pressure P in controlling bubble sizes. By a simple optimization of the channel geometry and Q and P, bubbles with a mean diameter of,5 mm can be obtained, ideal for various ultrasonic imaging applications. This method demonstrates the potential of microfluidics as an efficient means for custom-designing ultrasound contrast agents with precise size distributions, different gas compositions and new shell materials for stabilization, and for future targeted imaging and therapeutic applications.
引用
收藏
页码:463 / 468
页数:6
相关论文
共 36 条
[1]   Formation of dispersions using "flow focusing" in microchannels [J].
Anna, SL ;
Bontoux, N ;
Stone, HA .
APPLIED PHYSICS LETTERS, 2003, 82 (03) :364-366
[2]   Lateral phase separation in lipid-coated microbubbles [J].
Borden, MA ;
Martinez, GV ;
Ricker, J ;
Tsvetkova, N ;
Longo, M ;
Gillies, RJ ;
Dayton, PA ;
Ferrara, KW .
LANGMUIR, 2006, 22 (09) :4291-4297
[3]   Surface phase behavior and microstructure of lipid/PEG-emulsifier monolayer-coated microbubbles [J].
Borden, MA ;
Pu, G ;
Runner, GJ ;
Longo, ML .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2004, 35 (3-4) :209-223
[4]   High-temperature microfluidic synthesis of CdSe nanocrystals in nanoliter droplets [J].
Chan, EM ;
Alivisatos, AP ;
Mathies, RA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (40) :13854-13861
[5]   A prototype two-dimensional capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Chen, XX ;
Wu, HK ;
Mao, CD ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1772-1778
[6]   Introduction to ultrasound contrast agents: physics overview [J].
Dalla Palma, L ;
Bertolotto, M .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S338-S342
[7]   Targeted imaging using ultrasound [J].
Dayton, PA ;
Ferrara, KW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (04) :362-377
[8]   PARENCHYMAL ENHANCEMENT AND TUMOR VISUALIZATION USING A NEW SONOGRAPHIC CONTRAST AGENT [J].
FORSBERG, F ;
LIU, JB ;
MERTON, DA ;
RAWOOL, NM ;
GOLDBERG, BB .
JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (12) :949-957
[9]   Perfectly monodisperse microbubbling by capillary flow focusing -: art. no. 274501 [J].
Gañán-Calvo, AM ;
Gordillo, JM .
PHYSICAL REVIEW LETTERS, 2001, 87 (27)
[10]  
Garstecki P., 2005, Bulletin of the Polish Academy of Sciences, Technical Sciences, V53, P361, DOI 10.4064/ba53-4-2