Comparison of different clean-up procedures for the determination of N-methylcarbamate insecticides in vegetable matrices by high-performance liquid chromatography with UV detection

被引:60
作者
Nunes, GS
Ribeiro, ML
Polese, L
Barceló, D
机构
[1] CSIC, Cid, Dept Environm Chem, ES-08034 Barcelona, Spain
[2] Fed Univ Maranhao, Dept Chem Technol, BR-65080040 Sao Luis Ma, Brazil
[3] UNESP, Inst Chem, BR-14800900 Araraquara, SP, Brazil
关键词
sample preparation; vegetables; food analysis; pesticides; carbamates;
D O I
10.1016/S0021-9673(97)01176-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several clean-up procedures which included the use of glass chromatography columns (silica gel, alumina, Florisil, silanized Celite-charcoal), Sep-Pak cartridges and standard solutions were compared for the determination of the following N-methylcarbamate (NMC) insecticides: aldicarb, carbaryl, carbofuran, methomyl and propoxur. According to recovery results of the compounds after elution in a glass column, the most efficient systems employed 4.6% deactivated alumina and a silanized Celite-charcoal (4:1) as adsorbents, using dichloromethane-methanol (99:1) and toluene-acetonitrile (75:25) mixtures, respectively, as binary eluents. The recoveries of the compounds studied varied from 84 to 120%. Comparable recoveries (75-100%) for Sep-Pak cartridges in normal phase (NH2, CN) and reversed phase (C-8) were observed. Different temperatures were tested during the concentration step in a rotary evaporator, and we verified a strong influence of this parameter on the stability of some compounds, such as carbofuran and carbaryl. Recovery studies employing the best clean up procedures were performed at the Brazilian agricultural level in potato and carrot samples; Validation methodology of the US Food and Drug Administration was adapted for the N-methylcarbamate analysis. Their recoveries ranged between 79 and 93% with coefficients of variation of 2.3-8%. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 18 条
[1]   USE OF EXTRACTION DISKS FOR TRACE ENRICHMENT OF VARIOUS PESTICIDES FROM RIVER WATER AND SIMULATED SEAWATER SAMPLES FOLLOWED BY LIQUID-CHROMATOGRAPHY RAPID-SCANNING UV VISIBLE AND THERMOSPRAY MASS-SPECTROMETRY DETECTION [J].
BARCELO, D ;
DURAND, G ;
BOUVOT, V ;
NIELEN, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (02) :271-277
[2]  
BERTRAND N, 1991, ANAL CHIM ACTA, V254, P235
[3]   EXTRACTION, CLEANUP AND LIQUID CHROMATOGRAPHIC-DIODE ARRAY DETERMINATION OF CARBAMATE PESTICIDES IN SOIL SAMPLES [J].
DEBERTRAND, N ;
DURAND, G ;
BARCELO, D .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1991, 26 (04) :575-597
[4]   IMPROVED CLEANUP METHOD FOR THE MULTIRESIDUE ANALYSIS OF N-METHYLCARBAMATES IN GRAINS, FRUITS AND VEGETABLES BY MEANS OF HPLC WITH POSTCOLUMN REACTION AND FLUORESCENCE DETECTION [J].
DEKOK, A ;
HIEMSTRA, M ;
VREEKER, CP .
CHROMATOGRAPHIA, 1987, 24 :469-476
[5]  
Durand G., 1994, Quimica Analitica, V13, pS89
[6]  
Hassal K. A., 1983, CHEM PESTICIDES THEI
[7]   SIMULTANEOUS ANALYSIS OF 25 PESTICIDES IN CROPS USING GAS-CHROMATOGRAPHY AND THEIR IDENTIFICATION BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HONG, JK ;
EO, YW ;
RHEE, JS ;
KIM, TJ ;
KIM, KJ .
JOURNAL OF CHROMATOGRAPHY, 1993, 639 (02) :261-271
[8]   EFFECT OF ION-SOURCE PRESSURE AN ION FORMATION OF CARBAMATES IN PARTICLE-BEAM CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
HONING, M ;
BARCELO, D ;
JAGER, ME ;
SLOBODNIK, J ;
VANBAAR, BLM ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :21-30
[9]  
*ILSE BRAZ INT LIF, 1995, REL SUBST US FIT DOM
[10]  
KRAUSE RT, 1980, J ASSOC OFF ANA CHEM, V63, P1114