Estimation of blood velocity with high frequency ultrasound

被引:44
作者
Ferrara, KW
Zagar, BG
SokilMelgar, JB
Silverman, RH
Aslanidis, IM
机构
[1] GRAZ UNIV,GRAZ,AUSTRIA
[2] RIVERSIDE RES INST,NEW YORK,NY
[3] CORNELL UNIV,COLL MED,NEW YORK,NY
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.484474
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In order to map blood velocity in small regions near the transducer, we evaluate the performance of the wideband maximum likelihood (WMLE) strategy and infinite impulse response (IIR) filters for blood velocity estimation with a transducer center frequency of 38 MHz. Using a short transmitted pulse and the narrow lateral beam width obtained using this frequency, we show that velocities smaller than 1 mm/s can be estimated reliably. In addition, using both changes in the location and magnitude of the peak of the RF correlation, vessels as small as 40 mu m can be visualized in the RF signal and distinguished from stationary tissue. The experimental system also provides the opportunity to examine changes in flow and in the vessel wall over a cardiac cycle.
引用
收藏
页码:149 / 157
页数:9
相关论文
共 11 条
[1]   INITIALIZATION FOR IMPROVED IIR FILTER PERFORMANCE [J].
CHORNOBOY, ES .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1992, 40 (03) :543-550
[2]   CYCLIC CHANGES OF BLOOD ECHOGENICITY IN HIGH-FREQUENCY ULTRASOUND [J].
DEKROON, MGM ;
SLAGER, CJ ;
GUSSENHOVEN, WJ ;
SERRUYS, PW ;
ROELANDT, JRTC ;
BOM, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07) :723-728
[3]   A STATISTICAL-ANALYSIS OF THE RECEIVED SIGNAL FROM BLOOD DURING LAMINAR-FLOW [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (02) :185-198
[4]   A NEW WIDE-BAND SPREAD TARGET MAXIMUM-LIKELIHOOD ESTIMATOR FOR BLOOD VELOCITY ESTIMATION .1. THEORY [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :1-16
[5]   A THEORETICAL AND EXPERIMENTAL-ANALYSIS OF THE RECEIVED SIGNAL FROM DISTURBED BLOOD-FLOW [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (02) :172-184
[6]  
FERRARA KW, UNPUB ULTRASOUND MED
[7]   AN EFFICIENT ALGORITHM TO REMOVE LOW-FREQUENCY DOPPLER SIGNALS IN DIGITAL DOPPLER SYSTEMS [J].
HOEKS, APG ;
VANDEVORST, JJW ;
DABEKAUSSEN, A ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1991, 13 (02) :135-144
[8]  
LIZZI FL, 1978, ANN OPHTHALMOL, V10, P934
[9]   MEASUREMENT OF THE ULTRASONIC PROPERTIES OF VASCULAR TISSUES AND BLOOD FROM 35-65 MHZ [J].
LOCKWOOD, GR ;
RYAN, LK ;
HUNT, JW ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07) :653-666
[10]  
LOCKWOOD GR, 1990, ULTRASON S P, V3, P1409