Commissioning of OPHELIE in the DC mode:: an electromagnetic planar/helical crossed VUV undulator at super-ACO

被引:13
作者
Nahon, L
Thissen, R
Alcaraz, C
Corlier, M
Peaupardin, P
Marteau, F
Marcouillé, O
Brunelle, P
机构
[1] Univ Paris Sud, LURE, F-91898 Orsay, France
[2] CE Saclay, CEA, DRECAM, SPAM, F-91191 Gif Sur Yvette, France
[3] Univ Paris Sud, LPCR, F-91405 Orsay, France
关键词
synchrotron radiation; insertion device; electromagnetic undulator; magnetic measurements; particle beam dynamics;
D O I
10.1016/S0168-9002(99)01278-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OPHELIE is a crossed Onuki-type fixed-gap electromagnetic undulator capable of producing any polarization state of the emitted light in the VUV by setting its three main parameters: the vertical and horizontal driving currents and the longitudinal dephasing phi. After its construction in accordance with strict mechanical tolerances, the undulator was magnetically checked and calibrated with both a Hall probe and the pulsed wire technique showing a very satisfactory behavior with, in particular, a high horizontal/vertical symmetry. OPHELIE has been then the object of a full on-beam commissioning in the DC mode. The effects on the positron beam, in terms of closed orbit distortion and betatron tune shifts, have been calibrated and fully analyzed. The promising results gained during the magnetic measurement campaign have been confirmed by the spectral characteristics of the undulator which are very satisfactory: full tunability of the fundamental between 4.7 and 20 eV, validation of the superimposition principle of the magnetic fields, and stability of the spectra with respect to a polarity/dephasing switch. Besides, an unexpected phi-dependence of the emitted wavelength has been unravelled and will be taken into account in the computer control of the undulator. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:569 / 586
页数:18
相关论文
共 23 条
[1]   First polarization measurements of OPHELIE: a versatile polarization VUV undulator at Super-ACO [J].
Alcaraz, C ;
Thissen, R ;
Compin, M ;
Jolly, A ;
Drescher, M ;
Nahon, L .
X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 :250-261
[2]  
BRUNELLE P, 1999, P PAC 99 NEW YORK, P2686
[3]  
CASSINARI L, 1999, P PAC 99 NEW YORK 22
[4]  
CHAVANNE J, 1998, P EPAC 98 STOCKH JUN
[5]  
Desiderio D., 1999, Synchrotron Radiat. News, V12, P34, DOI DOI 10.1080/08940889908261012
[6]   GENERATION OF VARIOUS POLARIZATION STATES FROM INSERTION DEVICES - A REVIEW [J].
ELLEAUME, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1830-1833
[7]   HELIOS - A NEW-TYPE OF LINEAR HELICAL UNDULATOR [J].
ELLEAUME, P .
JOURNAL OF SYNCHROTRON RADIATION, 1994, 1 :19-26
[8]  
Kim K.-J., 1989, AIP CONF P, V184, P565
[9]  
KIM KJ, 1990, SPIE P, V1345, P116
[10]  
*LURE, SU59820 LURE