Enzyme activity control by responsive redoxpolymers

被引:62
作者
Nagel, Birgit
Warsinke, Axel
Katterle, Martin
机构
[1] Faunhofer Inst Biomed Engn, D-14476 Potsdam, Germany
[2] Univ Potsdam, D-14476 Potsdam, Germany
关键词
D O I
10.1021/la700331w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new thermoresponsive poly-N-isopropylacrylamide (PNIPAM)-ferrocene polymer was synthesized and characterized. PNIPAMFoxy bears additional oxirane groups which were used for attachment by a self-assembly process on a cysteamine-modified gold electrode to create a thin hydrophilic film. The new redox polymer enabled electrical communication between the cofactor pyrrolinoquinoline quinone (PQQ) of soluble glucose dehydrogenase (sGDH) and the electrode for sensitive detection of this enzyme as a prospective protein label. The temperature influence on the redox polymer/enzyme complex was investigated. An inverse temperature response behavior of surface bound PNIPAMFoxy compared to the soluble polymer was found and is discussed in detail. The highest efficiency of mediated electron transfer for the immobilized PNIPAMFoxy with sGDH was observed at 24 degrees C, which was twice as high as that of its soluble counterpart. A steady-state electrooxidation current densitiy of 4.5 mu A center dot cm(-2) was observed in the presence of 10 nM sGDH and 5 mM glucose. A detection limit of 0.5 nM of soluble PQQ-sGDH was obtained.
引用
收藏
页码:6807 / 6811
页数:5
相关论文
共 29 条
[1]   Signal generation at an electrochemical immunosensor via the direct oxidation of an electroactive label [J].
Akram, M ;
Stuart, MC ;
Wong, DKY .
ELECTROANALYSIS, 2006, 18 (03) :237-246
[2]  
Armada MPG, 2003, ELECTROANAL, V15, P1109
[3]   A microstructured silicon membrane with entrapped hydrogels for environmentally sensitive fluid gating [J].
Baldi, A ;
Lei, M ;
Gu, YD ;
Siegel, RA ;
Ziaie, B .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :9-18
[4]   THE DEVELOPMENT OF REDOX-MODIFIED ELECTRODES AS CHARGE-ACCUMULATING DEVICES FOR USE IN HIGHER SENSITIVITY DETECTION SYSTEMS [J].
CHAMBERS, JA ;
WALTON, NJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 250 (02) :417-425
[5]   QUINOPROTEIN GLUCOSE-DEHYDROGENASE AND ITS APPLICATION IN AN AMPEROMETRIC GLUCOSE SENSOR [J].
DCOSTA, EJ ;
HIGGINS, IJ ;
TURNER, APF .
BIOSENSORS, 1986, 2 (02) :71-87
[6]   Conducting redoxpolymer-based reagentless biosensors using modified PQQ-dependent glucose dehydrogenase [J].
Habermüller, K ;
Reiter, S ;
Buck, H ;
Meier, T ;
Staepels, J ;
Schuhmann, W .
MICROCHIMICA ACTA, 2003, 143 (2-3) :113-121
[7]  
Habermüller L, 2000, FRESEN J ANAL CHEM, V366, P560
[8]   Controlled release of model drugs through a molecular recognition ion gating membrane in response to a specific ion signal [J].
Ito, T ;
Yamaguchi, T .
LANGMUIR, 2006, 22 (08) :3945-3949
[9]  
Jaouen G, 2006, BIOORGANOMETALLICS: BIOMOLECULES, LABELING, MEDICINE, P1
[10]   Electrodes modified with the phase transition polymer and heme peptide: Biocatalysis and biosensing with tunable activity and dynamic range [J].
Komori, K ;
Takada, K ;
Tatsuma, T .
LANGMUIR, 2006, 22 (01) :478-483