Optimized spiral imaging for measurement of myocardial T2 relaxation

被引:70
作者
Foltz, WD
Al-Kwifi, O
Sussman, MS
Stainsby, JA
Wright, GA
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Imaging Res Program, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] GE Med Syst, ASL West, Menlo Pk, CA USA
关键词
myocardial T2; spinal imaging; oximetry; BOLD-MRI;
D O I
10.1002/mrm.10467
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Microcirculation oxygen levels and blood volumes should be reflected in measurements of myocardial T-2 relaxation. This work describes the optimization of a spiral imaging strategy for robust myocardial T-2 measurement to minimize the standard deviation of T-2 measurement (sigmaT(2)). Theoretical and experimental studies of blurring at muscle/blood interfaces enabled the derivation of parameter sets which reduce sigma T-2 to the level of 5%. T-2 relaxation mapping within healthy volunteers provided estimation of residual sigmaT(2) within the optimized technique. The standard deviation in T-2 measurement across regions of interest (ROIs) in different locations is about 9%. The standard deviation in T-2 measurement in an ROI across different time points is about 5%. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1089 / 1097
页数:9
相关论文
共 30 条
  • [1] OXYGENATION IN THE RABBIT MYOCARDIUM - ASSESSMENT WITH SUSCEPTIBILITY-DEPENDENT MR-IMAGING
    ATALAY, MK
    FORDER, JR
    CHACKO, VP
    KAWAMOTO, S
    ZERHOUNI, EA
    [J]. RADIOLOGY, 1993, 189 (03) : 759 - 764
  • [2] Bauer WR, 1999, MAGN RESON MED, V41, P51, DOI 10.1002/(SICI)1522-2594(199901)41:1<51::AID-MRM9>3.0.CO
  • [3] 2-G
  • [4] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696
  • [5] STUDIES OF GD-DTPA RELAXIVITY AND PROTON-EXCHANGE RATES IN TISSUE
    DONAHUE, KM
    BURSTEIN, D
    MANNING, WJ
    GRAY, ML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) : 66 - 76
  • [6] FOLTZ W, 1998, P 6 SCI M ISMRM SYDN, V3, P2168
  • [7] T-2 accuracy on a whole-body imager
    Foltz, WD
    Stainsby, JA
    Wright, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) : 759 - 768
  • [8] Vasodilator response assessment in porcine myocardium with magnetic resonance relaxometry
    Foltz, WD
    Huang, H
    Fort, S
    Wright, GA
    [J]. CIRCULATION, 2002, 106 (21) : 2714 - 2719
  • [9] Foltz WD, 1999, MAGN RESON MED, V42, P837, DOI 10.1002/(SICI)1522-2594(199911)42:5<837::AID-MRM3>3.0.CO
  • [10] 2-8