Electrochemical corrosion behavior of biodegradable Mg-Y-RE and Mg-Zn-Zr alloys in Ringer's solution and simulated body fluid
被引:168
作者:
论文数: 引用数:
h-index:
机构:
Jamesh, Mohammed Ibrahim
[1
,2
]
Wu, Guosong
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
Wu, Guosong
[1
]
Zhao, Ying
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
Zhao, Ying
[1
]
McKenzie, David R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sydney, Sch Phys A28, Sydney, NSW 2006, AustraliaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
McKenzie, David R.
[2
]
Bilek, Marcela M. M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sydney, Sch Phys A28, Sydney, NSW 2006, AustraliaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
Bilek, Marcela M. M.
[2
]
Chu, Paul K.
论文数: 0引用数: 0
h-index: 0
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
Chu, Paul K.
[1
]
机构:
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Univ Sydney, Sch Phys A28, Sydney, NSW 2006, Australia
Magnesium;
IR spectroscopy;
EIS;
XPS;
PLASMA ION-IMPLANTATION;
IN-VIVO CORROSION;
MAGNESIUM ALLOY;
BIOMEDICAL APPLICATIONS;
PURE MAGNESIUM;
RESISTANCE;
BONE;
ZIRCONIUM;
PRECIPITATION;
BIOMATERIALS;
D O I:
10.1016/j.corsci.2014.11.015
中图分类号:
T [工业技术];
学科分类号:
120111 [工业工程];
摘要:
The corrosion behavior of WE43 and ZK60 Mg alloys are investigated in Ringer's solution and simulated body fluid (SBF). The major protective corrosion-products formed on both Mg alloys are crystalline aragonite form of CaCO3 and Mg(OH)(2) in Ringer's solution whereas Ca-10(PO4)(6)(OH)(2), Ca-3(PO4)(2)center dot 3H(2)O and Mg(OH)(2) in SBF. Electrochemical impedance spectroscopy reveals that in the initial stage, the increase in the corrosion resistance on both Mg alloys in Ringer's solution is more than 6 times than in SBF. Our study reveals higher R-p, larger impedance, and bigger phase angle maxima for WE43 than ZK60 after immersion in both solutions for 96 h. (C) 2014 Elsevier Ltd. All rights reserved.
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
机构:
City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R ChinaCity Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China