The use of a handheld calorimetry unit to estimate energy expenditure during different physiological conditions

被引:15
作者
Rubenbauer, Justine R. [1 ]
Johannsen, Darcy L. [1 ]
Baier, Shawn M. [1 ]
Litchfield, Ruth [1 ]
Flakoll, Paul J. [1 ]
机构
[1] Iowa State Univ, Dept Food Sci & Human Nutr, Ctr Designing Food Improve Nutr, Ames, IA 50011 USA
关键词
D O I
10.1177/0148607106030003246
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Accurately determining rates of energy expenditure (EE) under free-living conditions is important in understanding the mechanisms involved in the development and prevention of obesity. Metabolic carts are not portable enough for most free-living situations. The purpose of this study was to compare a portable, handheld indirect calorimetry device (HealtheTech Incorporated, Golden, CO) to a metabolic cart (Physio-Dyne Instrument Corporation, Quogue, NY) during 3 different physiologic states. Methods: EE was measured by both the handheld calorimeter (5-10 minutes) and the metabolic cart (15-20 minutes) in 20 healthy subjects (18-35 years of age). Measurements were made during 3 physiologic states: (1) postabsorptive rest (REE), (2) postprandial rest (fed energy expenditure, FEE), and (3) while walking in place (activity energy expenditure, the means of the cart us the handheld device for REE (mean +/- SE; kcal/d; 1552 +/- 64 us 1551 +/- 63), FEE (1875 +/- 99 us 1825 +/- 86), and AEE (3333 +/- 218 us 3489 +/- 152). The range over which the techniques were tested was 1300-5000 kcal/d. The agreement between the 2 methods was excellent for REE (0.80, p <.0001), FEE (0.89, p.5.0001), and AEE (0.75, P <.0002). Conclusions: Compared with the metabolic cart, the handheld device provided similar estimates of energy expenditure during resting, postprandial, and physically active states. This suggests that portable indirect calorimetry devices can provide reliable and valuable information in free-living research situations for which maximal energy expenditure is <5000 kcal/d.
引用
收藏
页码:246 / 250
页数:5
相关论文
共 18 条
[1]   Validity and reproducibility of resting metabolic rate measurements in rural Bangladeshi women:: comparison of measurements obtained by Medgem™ and by Deltatrac™ device [J].
Alam, DS ;
Hulshof, PJM ;
Roordink, D ;
Meltzer, M ;
Yunus, M ;
Salam, MA ;
van Raaij, JMA .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (05) :651-657
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Comparison between Medgem and Deltatrac resting metabolic rate measurements [J].
Compher, C ;
Hise, M ;
Sternberg, A ;
Kinosian, BP .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (10) :1136-1141
[4]  
Flancbaum L, 1999, AM J CLIN NUTR, V69, P461
[5]  
Harris J., 1919, BIOMETRIC STUDY BASA
[6]   LONG-TERM MEASUREMENTS OF ENERGY-EXPENDITURE IN HUMANS USING A RESPIRATION CHAMBER [J].
JEQUIER, E ;
SCHUTZ, Y .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1983, 38 (06) :989-998
[7]  
McClave S A, 1992, Nutr Clin Pract, V7, P207, DOI 10.1177/0115426592007005207
[8]   A NEW PREDICTIVE EQUATION FOR RESTING ENERGY-EXPENDITURE IN HEALTHY-INDIVIDUALS [J].
MIFFLIN, MD ;
STJEOR, ST ;
HILL, LA ;
SCOTT, BJ ;
DAUGHERTY, SA ;
KOH, YO .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (02) :241-247
[9]  
NEIMAN DC, 2003, J AM DIET ASSOC, V130, P588
[10]  
*PHYS INSTR CORP, MAX 2 MAN