摘要
In this study, a building with a volume of 351 m(3) and a net floor area of 117 m(2) is considered as a case study with the indoor and exterior air temperatures of 20 and 0 degrees C, respectively. For the heating applications, four options are studied with (1) a heat pump, (2) a condensing boiler, (3) a conventional boiler and (4) a solar collector, which are driven by renewable and non-renewable energy sources. An energy and exergy analysis is employed to assess their performances and compare them through energy and exergy efficiencies and sustainability index. Energy and exergy flows are investigated and illustrated. Also, the energetic and exergetic renewability ratios are utilized here along with sustainability index. The results show that overall exergy efficiencies of heat pump, condensing boiler, conventional boiler and solar heating systems are found to be 3.66, 3.31, 2.91, and 12.64%, while the sustainability index values for the four cases considered are calculated to be 1.039, 1.034, 1.030 and 1.144, respectively. So, solar collector-based heating system gives the highest efficiency and sustainability index values. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1320 / 1328
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2004, OIL CRIS CLIM CHALL
[2]  
ASADA H, 1999, P 6 INT IBPSA C KYOT, P121
[3]  
BAEHR HD, 1980, BRENNST-WARME-KRAFT, V32, P9
[4]   Evaluating a low exergy heating system from the power plant through the heat pump to the building envelope [J].
Balta, M. Tolga ;
Kalinci, Yildiz ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2008, 40 (10) :1799-1804
[5]  
Cornelissen R.L., 1997, Thermodynamics and sustainable development - The use of exergy analysis and the reduction of irreversibility
[6]   New energy and exergy parameters for geothermal district heating systems [J].
Coskun, C. ;
Oktay, Zuhal ;
Dincer, I. .
APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) :2235-2242
[7]  
GERTIS K, 1995, CLIM COMM INT CCI, V29, P134
[8]   A study on modeling and performance assessment of a heat pump system for utilizing low temperature geothermal resources in buildings [J].
Hepbasli, Arif ;
Balta, M. Tolga .
BUILDING AND ENVIRONMENT, 2007, 42 (10) :3747-3756
[9]  
*IEA, 2008, LOW EN HEAT COOL BUI
[10]  
JENNI J, 2002, HEIZUNGKLIMA, V29, P8