A filtration method for improving film dosimetry in photon radiation therapy

被引:34
作者
Yeo, IJ
Wang, CKC
Burch, SE
机构
[1] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
[2] Med Coll Georgia, Georgia Radiat Therapy Ctr, Augusta, GA 30912 USA
关键词
film-filter optimization; x-ray film dosimetry; Monte Carlo method;
D O I
10.1118/1.598108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Successful radiotherapy requires accurate dosimetry for treatment verification. Existing dosimeters such as ion chambers, TLD, and diodes have drawbacks such as relatively long measurement time and poor spatial resolution. These disadvantages become serious problems for dynamic-wedged beams. Thus the clinical use of dynamic wedges requires an improved dosimetry method. X-ray film may serve this purpose. However, x-ray film is not clinically accepted as a dosimeter for photon beams, because it overresponds to photons with energies below about 400 keV. This paper presents and develops a method which was initially proposed by Burch to improve the dose response of x-ray film in a phantom. The method is based on placing high-atomic number foils next to the film. The foils are used as filters to preferentially remove low-energy photons. The optimal film and filter configuration in a phantom was determined using a mathematical scheme derived in this study and a Monte Carlo technique (ITS code). The optimal configuration thus determined is as follows: the filter-to-film distance of 6 mm and the filter thickness of 0.15 mm for percent depth-dose measurement; the distance of I cm and the thickness of 0.25 mm for off-axis (dose) ratio measurement. The configuration was then tested with photon beams from a 4 MV linac. The test result indicates that the in-phantom dose distribution based on the optimal configuration agrees well with those measured by ion chambers. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1943 / 1953
页数:11
相关论文
共 29 条
[1]  
[Anonymous], 1983, MED PHYS, V10, P741
[2]  
[Anonymous], 1984, 35 ICRU
[3]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[4]  
BURCH SE, 1993, THESIS GEORGIA I TEC
[5]  
EHRLICH M, 1954, PHOTOGRAPHIC DOSIMET
[6]  
GRANKE RC, 1954, AM J ROENTGENOL, V72, P302
[7]   THE PHOTOGRAPHIC ACTION OF X-RAYS [J].
GREENING, JR .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1951, 64 (383) :977-992
[8]  
Halbleib J A, 1992, SAND911634 SAND NAT
[9]  
HEARD MJ, 1965, J PHOTOGR SCI, V13, P32
[10]   PRECISION IN RADIATION ONCOLOGY [J].
HENDRICKSON, FR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (02) :311-312