Development of fast enantioselective gas-chromatographic analysis using gas-chromatographic method-translation software in routine essential oil analysis (lavender essential oil)

被引:30
作者
Bicchi, Carlo [1 ]
Blumberg, Leonid [2 ]
Cagliero, Cecilia [1 ]
Cordero, Chiara [1 ]
Rubiolo, Patrizia [1 ]
Liberto, Erica [1 ]
机构
[1] Univ Turin, Fac Farm, Dipartimento Sci & Tecnol Farm, I-10125 Turin, Italy
[2] Fast GC Consulting, Wilmington, DE 19801 USA
关键词
Enantioselective GC; Fast enantioselective GC; Cyclodextrin derivatives; Method-translation software; Efficiency-optimized flow (EOF); Speed-optimized flow (SOF); Lavender essential oil; CYCLODEXTRIN DERIVATIVES; CHIRAL SELECTORS; SEPARATION; ENANTIOMERS;
D O I
10.1016/j.chroma.2010.01.003
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
The study aimed to find the best trade-off between separation of the most critical peak pair and analysis time, in enantioselective GC-FID and CC-MS analysis of lavender essential oil, using the CC method-translation approach. Analysis conditions were first optimized for conventional 25 m x 0.25 mm inner diameter (d(c)) column coated with 6(I-VII)-O-tert-butyldimethylsilyl-2(I-VII)-3(I-VII)-O-ethyl-beta-cyclodextrin (CD) as chiral stationary phase (CSP) diluted at 30% in PS086(polymethylphenylpolysiloxane, 15% phenyl), starting from routine analysis. The optimal multi-rate temperature program for a pre-set column pressure was determined and then used to find the pressures producing the efficiency-optimized flow (EOF) and speed-optimized flow (SOF). This method was transferred to a shorter narrow-bore (NB) column (11 m x 0.10 mm) using method-translation software, keeping peak elution order and separation. Optimization of the enantioselective CC method with the translation approach markedly reduced the analysis time of the lavender essential oil, from about 87 min with the routine method to 40 min with an optimal multi-rate temperature program and initial flow with a conventional inner diameter column, and to 15 min with FID as detector or 13.5 min with MS with a corresponding narrow-bore column, while keeping enantiomer separation and efficiency (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1530 / 1536
页数:7
相关论文
共 19 条
[1]
[Anonymous], 2008, European Pharmacopoeia, V6th
[2]
Cyclodextrin derivatives as chiral selectors for direct gas chromatographic separation of enantiomers in the essential oil, aroma and flavour fields [J].
Bicchi, C ;
D'Amato, A ;
Rubiolo, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :99-121
[3]
Cyclodextrin derivatives in the gas chromatographic separation of racemic mixtures of volatile compounds .10. 2,3-Di-O-ethyl-6-O-tert-butyldimethylsilyl-beta- and -gamma-cyclodextrins [J].
Bicchi, C ;
DAmato, A ;
Manzin, V ;
Galli, A ;
Galli, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 742 (1-2) :161-173
[4]
Conventional and narrow bore short capillary columns with cyclodextrin derivatives as chiral selectors to speed-up enantioselective gas chromatography and enantioselective gas chromatography-mass spectrometry analyses [J].
Bicchi, Carlo ;
Liberto, Erica ;
Cagliero, Cecilia ;
Cordero, Chiara ;
Sgorbini, Barbara ;
Rubiolo, Patrizia .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) :114-123
[5]
Blumberg LM, 2000, J MICROCOLUMN SEP, V12, P508, DOI 10.1002/1520-667X(2000)12:9<508::AID-MCS5>3.0.CO
[6]
2-Y
[7]
Evaluation of column performance in constant pressure and constant flow capillary gas chromatography [J].
Blumberg, LM ;
Wilson, WH ;
Klee, MS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :15-28
[8]
Blumberg LM, 1997, HRC-J HIGH RES CHROM, V20, P679
[9]
Blumberg LM, 1997, HRC-J HIGH RES CHROM, V20, P597
[10]
Method translation and retention time locking in partition GC [J].
Blumberg, LM ;
Klee, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3828-3839