Renal cysts: Is attenuation artifactually increased on contrast-enhanced CT images?

被引:67
作者
Bae, KT [1 ]
Heiken, JP [1 ]
Siegel, CL [1 ]
Bennett, HF [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
computed tomography (CT); contrast enhancement; helical; kidney; CT; cysts;
D O I
10.1148/radiology.216.3.r00se14792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if the attenuation values of simple renal cysts are artifactually increased on contrast material-enhanced, clinically acquired spiral computed tomographic (CT) images. MATERIALS AND METHODS: Dual-phase renal spiral CT studies (5-mm collimation; pitch, 1.0) were retrospectively analyzed in 24 consecutive patients who had ultrasonographic (US) documentation of simple renal cysts. Forty-eight cysts were identified. The attenuation values of each cyst were measured on nonenhanced, cortical phase, and nephrographic phase images. The size and the location of each cyst in relation to the renal parenchyma were also recorded. RESULTS: The cysts were 0.6-10.8 cm in diameter (mean, 2.6 cm; SD, 2.0). The mean attenuation change in the cysts from nonenhanced to contrast-enhanced images was statistically significant in a comparison of cortical phase and nephrographic phase images (P < .01): +1.8 HU (SD, 3.8) for cortical phase and +3.6 HU (SD, 5.6) for nephrographic phase images. Renal cysts 1.0 cm or smaller showed a higher attenuation increase (mean, +4.0 HU for cortical phase and +11.0 HU for nephrographic phase). None of the renal cysts larger than 1.0 cm demonstrated an increase greater than 10 HU (mean, +1.4 HU for cortical phase and +2.3 HU for nephrographic phase). Intraparenchymal cysts showed higher mean attenuation changes than the exophytic cysts. CONCLUSION: Attenuation Values in the renal cysts increased artifactually on contrast-enhanced images, but this pseudoenhancement was not substantial and was less than 10 HU when the cyst was larger than 1.0 cm in diameter.
引用
收藏
页码:792 / 796
页数:5
相关论文
共 11 条
[1]   Multiphasic renal CT: Comparison of renal mass enhancement during the corticomedullary and nephrographic phases [J].
Birnbaum, BA ;
Jacobs, JE ;
Ramchandani, P .
RADIOLOGY, 1996, 200 (03) :753-758
[2]   Problems in the detection and characterization of small renal masses [J].
Bosniak, MA ;
Rofsky, NM .
RADIOLOGY, 1996, 198 (03) :638-641
[3]  
BOSNIAK MA, 1986, RADIOLOGY, V158, P1
[5]   Radiologic assessment of renal masses: Implications for patient care [J].
Davidson, AJ ;
Hartman, DS ;
Choyke, PL ;
Wagner, BJ .
RADIOLOGY, 1997, 202 (02) :297-305
[6]   The effect of helical CT on X-ray attenuation [J].
Hopper, KD ;
Gouldy, CA ;
Kasales, CJ ;
TenHave, TR ;
Fisher, AL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :152-155
[7]  
HOPPER KD, 1995, RADIOLOGY, V197, P147
[8]   AGING AND SIMPLE CYSTS OF THE KIDNEY [J].
LAUCKS, SP ;
MCLACHLAN, MSF .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (637) :12-14
[9]   Renal cyst pseudoenhancement: Beam-hardening effects on CT numbers [J].
Maki, DD ;
Birnbaum, BA ;
Chakraborty, DP ;
Jacobs, JE ;
Carvalho, BM ;
Herman, GT .
RADIOLOGY, 1999, 213 (02) :468-472
[10]   Interobserver variability in determining enhancement of renal masses on helical CT [J].
Siegel, CL ;
Fisher, AJ ;
Bennett, HF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1207-1212