Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid

被引:283
作者
Alexeev, VL
Das, S
Finegold, DN
Asher, SA [1 ]
机构
[1] Univ Pittsburgh, Chevron Sci Ctr, Dept Chem, Sch Med, Pittsburgh, PA 15260 USA
[2] Glucose Sensing Technol LLC, Pittsburgh, PA USA
关键词
D O I
10.1373/clinchem.2004.039701
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We recently developed a photonic crystal glucose-sensing material (Alexeev et al., Anal Chem 2003;75:2316-23), which consists of a crystalline colloidal array embedded within a polymer network of a polyacrylamide-poly(ethylene glycol) hydrogel with pendent phenylboronic acid groups. The aim of the present work was to improve this approach for application to noninvasive or minimally invasive monitoring of glucose. Methods: We used new boronic acid derivatives such as 4-amino-3-fluorophenylboronic acid and 4-carboxy-3fluorophenylboronic acid as the molecular recognition elements to achieve sensing at physiologic pH values. Results: The improved photonic glucose-sensing material sensed glucose in the range of the 100 mumol/L concentrations found in tear fluid. The detection limits were similar to1 mumol/L in synthetic tear fluid. The visually evident diffraction color shifted across the entire visible spectral region from red to blue over the physiologically relevant tear-fluid glucose concentrations. This sensing material is selective for glucose over galactose, mannose, and fructose. Conclusions: These new glucose sensors have properties appropriate for use in such glucose-sensing applications as ocular inserts or diagnostic contact lenses for patients with diabetes mellitus. (C) 2004 American Association for Clinical Chemistry.
引用
收藏
页码:2353 / 2360
页数:8
相关论文
共 47 条
[1]  
ABELSON MB, 1981, ARCH OPHTHALMOL-CHIC, V99, P301
[2]   High ionic strength glucose-sensing photonic crystal [J].
Alexeev, VL ;
Sharma, AC ;
Goponenko, AV ;
Das, S ;
Lednev, IK ;
Wilcox, CS ;
Finegold, DN ;
Asher, SA .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2316-2323
[3]  
ALTMAN PL, 1974, BIOL DATA BOOK, P1819
[4]   A membrane-moderated, conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions [J].
Arnold, FH ;
Zheng, WG ;
Michaels, AS .
JOURNAL OF MEMBRANE SCIENCE, 2000, 167 (02) :227-239
[5]   Photonic crystal carbohydrate sensors: Low ionic strength sugar sensing [J].
Asher, SA ;
Alexeev, VL ;
Goponenko, AV ;
Sharma, AC ;
Lednev, IK ;
Wilcox, CS ;
Finegold, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (11) :3322-3329
[6]   Polymerized crystalline colloidal array chemical-sensing materials for detection of lead in body fluids [J].
Asher, SA ;
Peteu, SF ;
Reese, CE ;
Lin, MX ;
Finegold, D .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) :632-638
[7]   A fluorescent glucose sensor binding covalently to all five hydroxy groups of α-D-glucofuranose.: A reinvestigation [J].
Bielecki, M ;
Eggert, H ;
Norrild, JC .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1999, (03) :449-455
[8]  
BURTIS CA, 1999, TIETZ TXB CLIN CHEM, P782
[9]   HUMAN TEAR PH - DIURNAL-VARIATIONS [J].
CARNEY, LG ;
HILL, RM .
ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (05) :821-824
[10]  
CARNEY LG, 1991, CONSIDERATIONS CONTA, P34