Quantitative analysis of major, minor and trace elements in fluid inclusions using laser ablation inductively coupled plasma mass spectrometry

被引:311
作者
Gunther, D [1 ]
Audetat, A [1 ]
Frischknecht, R [1 ]
Heinrich, CA [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Isotope Geol & Mineral Resources, CH-8092 Zurich, Switzerland
关键词
laser ablation; inductively coupled plasma mass spectrometry; excimer; fluid inclusion;
D O I
10.1039/a707372k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microscopic fluid inclusions in minerals are the main source of information about the chemical composition of fluids associated with large-scale material transport in the Earth's interior, Hydrothermal transport processes are responsible for the natural enrichment of metal resources in many ore deposits, For the multi-element analysis of the microscopic fluid inclusions (typically 5-50 mu m in diameter), LA-ICP-MS has become one of the most promising techniques owing to the recent progress in laser optics design and the development of high-sensitivity ICP mass spectrometers, The quantitative analyses of 19 major, minor and trace elements covering a concentration range of five orders of magnitude were carried out on 39 single natural fluid inclusions, together with a number of experiments to optimise controlled ablation and to test the calibration procedure, A modified commercial ICP-MS instrument was used together with a prototype ablation system based on a 193 nm excimer laser, In a stepwise opening procedure for complex polyphase inclusions, a small hole (4 mu m pit) was first drilled for the partial release of liquid and vapor, followed by complete drilling out using a pit covering the entire inclusion, Controlled ablation improves the reproducibility of element ratios to less than 20% for most major, minor and trace elements measured in an assemblage of cogenetic inclusions (including elements that are initially present as solid precipitates within the inclusion), provided that the entire transient ICP-MS signal is integrated, Element ratios were calculated from integrated intensity ratios using an external standard, either a NIST SRM, glass or an aqueous standard solution ablated directly through a plastic film, Absolute concentrations were calculated from the element ratios via an internal standard element, whose concentration was determined prior to ablation, Microthermometric measurements of phase transitions were used to determine total salinity from known phase diagrams, by measuring either the depression of ice-melting temperature, or the temperature of dissolution of NaCl crystals, Salinity can be related to the concentration of Na (or in some cases C1), which serves as the internal standard element for the quantification of trace element concentrations, Calculated limits of detection are in the ng g(-1) to mu g g(-1) region, depending on the volume of the inclusions, The accuracy of the overall analysis, including internal and external calibration, is typically between 5 and 20%, as demonstrated on alkali elements in synthetic fluid inclusions of known composition.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 20 条
[1]  
Bodnar R.J., 1994, Fluid inclusions in minerals: Methods and applications: International Mineralogical Association Short Course Manual, P117
[2]   SYNTHETIC FLUID INCLUSIONS IN NATURAL QUARTZ .3. DETERMINATION OF PHASE-EQUILIBRIUM PROPERTIES IN THE SYSTEM H2O-NACL TO 1000-DEGREES-C AND 1500 BARS [J].
BODNAR, RJ ;
BURNHAM, CW ;
STERNER, SM .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1985, 49 (09) :1861-1873
[3]   A MODIFIED CRUSH-LEACH METHOD FOR THE ANALYSIS OF FLUID INCLUSION ELECTROLYTES [J].
BOTTRELL, SH ;
YARDLEY, B ;
BUCKLEY, F .
BULLETIN DE MINERALOGIE, 1988, 111 (3-4) :279-290
[4]  
DUBESSY J, 1989, EUR J MINERAL, V1, P517
[5]   New quantitative approach in trace elemental analysis of single fluid inclusions: Applications of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) [J].
Ghazi, AM ;
McCandless, TE ;
Vanko, DA ;
Ruiz, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :667-674
[6]   Direct liquid ablation: a new calibration strategy for laser ablation ICP-MS microanalysis of solids and liquids [J].
Gunther, D ;
Frischknecht, R ;
Muschenborn, HJ ;
Heinrich, CA .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :390-393
[7]   Capabilities of an Argon Fluoride 193 nm excimer laser for laser ablation inductively coupled plasma mass spectrometry microanalysis of geological materials [J].
Gunther, D ;
Frischknecht, R ;
Heinrich, CA ;
Kahlert, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :939-944
[8]   BR/CL GEOCHEMISTRY OF HYDROTHERMAL BRINES ASSOCIATED WITH PROTEROZOIC METASEDIMENT-HOSTED COPPER MINERALIZATION AT MOUNT ISA, NORTHERN AUSTRALIA [J].
HEINRICH, CA ;
BAIN, JHC ;
FARDY, JJ ;
WARING, CL .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1993, 57 (13) :2991-3000
[9]   SEGREGATION OF ORE METALS BETWEEN MAGMATIC BRINE AND VAPOR - A FLUID INCLUSION STUDY USING PIXE MICROANALYSIS [J].
HEINRICH, CA ;
RYAN, CG ;
MERNAGH, TP ;
EADINGTON, PJ .
ECONOMIC GEOLOGY AND THE BULLETIN OF THE SOCIETY OF ECONOMIC GEOLOGISTS, 1992, 87 (06) :1566-1583
[10]   Chemical mass transfer modelling of ore-forming hydrothermal systems: Current practise and problems [J].
Heinrich, CA ;
Walshe, JL ;
Harrold, BP .
ORE GEOLOGY REVIEWS, 1996, 10 (3-6) :319-338