Open wedge high tibial osteotomy: Biomechanical investigation of the modified Arthrex Steotomy Plate (Puddu Plate) and the TomoFix Plate

被引:169
作者
Stoffel, K
Stachowiak, G
Kuster, M
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle Hosp, Fremantle, WA 6160, Australia
[2] Univ Western Australia, Dept Mech & Mat Engn, Crawley, WA 6009, Australia
关键词
opening wedge tibial valgisation osteotomy; Arthrex Osteotomy Plate; TomoFix plate; stiffness; failure;
D O I
10.1016/j.clinbiomech.2004.06.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Objective. To determine the biomechanical properties of different fixation methods for high tibial medial opening wedge osteotomy in order to determine appropriate surgical and rehabilitation guidelines. Design. A biomechanical testing examined the construct stiffness and the fixation strength of two different plates. Background. Although medial opening wedge techniques for high tibial osteotomies have become popular in recent years, biomechanical data of frequently used implants is lacking. Methods. A 15-mm medial opening gap was stabilized in each of eight medium composite tibial bones either with the modified Arthrex Osteotomy Plate (Puddu Plate) or the TomoFix Plate. Results. Both constructs failed under compression and torsion at the lateral cortex and occurred at higher maximal forces by using the TomoFix Plate. After fracture of the lateral cortex the axial stiffness was reduced by 47% and the torsional rigidity by 54% for the TomoFix. For the Puddu Plate these reductions were 66% and 78%, respectively. The differences between the two groups were significant in all conducted tests (P < 0.05). Conclusions. This study indicates that an unharmed lateral hinge largely dictates the stability after high tibial osteotomy. If the lateral cortex is injured, the TomoFix plate provides superior stability in both compression and torsion compared to the Puddu Plate. In the latter case additional fixation might be considered. Relevance These biomechanical tests helped to identify clinical situations in which the mechanical attributes of the plates would prove advantageous. Crown Copyright (C) 2004 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:944 / 950
页数:7
相关论文
共 27 条
[1]
Contributions of proximal and distal moments to axial tibial rotation during walking and running [J].
Bellchamber, TL ;
van den Bogert, AJ .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1397-1403
[2]
Total knee arthroplasty after failed proximal tibial valgus osteotomy [J].
Bergenudd, H ;
Sahlstrom, A ;
Sanzen, L .
JOURNAL OF ARTHROPLASTY, 1997, 12 (06) :635-638
[3]
Bland M., 2000, STAT QUESTIONS EVIDE
[4]
Calista F, 1996, Chir Organi Mov, V81, P155
[5]
Mechanical validation of whole bone composite tibia models [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :279-288
[6]
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[7]
High tibial osteotomy - primary stability of several implants [J].
Flamme, CH ;
Kohn, D ;
Kirsch, L .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1999, 137 (01) :48-53
[8]
Flierl S, 1996, Knee Surg Sports Traumatol Arthrosc, V4, P149, DOI 10.1007/BF01577407
[9]
MECHANICAL PROPERTIES OF SURGICAL BONE SCREWS AND SOME ASPECTS OF INSERTION PRACTICE [J].
HUGHES, AN ;
JORDAN, BA .
INJURY-THE BRITISH JOURNAL OF ACCIDENT SURGERY, 1972, 4 (01) :25-&
[10]
HIGH TIBIAL OSTEOTOMY FOR VARUS GONARTHROSIS - A LONG-TERM FOLLOW-UP-STUDY [J].
INSALL, JN ;
JOSEPH, DM ;
MSIKA, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (07) :1040-1048