摘要
The results of a study on the fine structural distortion due to the two previously observed types of degradation in cyclically loaded single osteons (i.e., stiffness degradation and pinching effect) are presented. Fully calcified longitudinal and alternate osteons were isolated from 350-mu m-thick longitudinal sections of human femoral cortical bone. The samples were prepared from 500-mu m-long central cylindrical portions of an osteon, whose two ends were penetrating into rectangular lugs for fixation to an electromechanical device that cyclically loaded the samples. This device was connected to a microwave micrometer and a recorder. The structural distortions induced by cyclic loading were investigated by high-and low-angle X-ray diffraction on conventional and synchrotron radiation sources. Cyclic loading results in a reduction in the degree of orientation of apatite crystallites, especially in longitudinal osteons, in which the most abundant longitudinal lamellae are not protected against buckling by transverse lamellae as they are in alternate osteons. In contrast, the degree of orientation of collagen fibrils does not seem to be affected by cycling loading in the two osteon types, possibly because the disorientation of collagen fibrils is, within limits, a reversible process. Finally, the contrast between the disorientation of inorganic crystallites and the apparently unaltered distribution of collagen fibrils suggests that the degradation of cyclically loaded osteons may be due to a separation of the crystallites from the fibrils.
引用
收藏
页码:266 / 273
页数:8
相关论文
共 39 条
  • [1] Alexander L.E., 1969, XRAY DIFFRACTION MET
  • [2] AMPRINO R, 1952, ACTA ANAT, V15, P1
  • [3] CRYSTALS IN CALCIFIED EPIPHYSEAL CARTILAGE AND CORTICAL BONE OF THE RAT
    ARSENAULT, AL
    GRYNPAS, MD
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (04) : 219 - 225
  • [4] A COMPARATIVE ELECTRON-MICROSCOPIC STUDY OF APATITE CRYSTALS IN COLLAGEN FIBRILS OF RAT BONE, DENTIN AND CALCIFIED TURKEY LEG TENDONS
    ARSENAULT, AL
    [J]. BONE AND MINERAL, 1989, 6 (02): : 165 - 177
  • [5] A LOW-ANGLE X-RAY-DIFFRACTION ANALYSIS OF OSTEONIC INORGANIC PHASE USING SYNCHROTRON RADIATION
    ASCENZI, A
    BIGI, A
    KOCH, MHJ
    RIPAMONTI, A
    ROVERI, N
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1985, 37 (06) : 659 - 664
  • [6] ORIENTATION OF APATITE IN SINGLE OSTEON SAMPLES AS STUDIED BY POLE FIGURES
    ASCENZI, A
    BONUCCI, E
    GENERALI, P
    RIPAMONTI, A
    ROVERI, N
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1979, 29 (02) : 101 - 105
  • [7] MECHANICAL HYSTERESIS LOOPS FROM SINGLE OSTEONS - TECHNICAL DEVICES AND PRELIMINARY-RESULTS
    ASCENZI, A
    BENVENUTI, A
    MANGO, F
    SIMILI, R
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (05) : 391 - 398
  • [8] Pinching in longitudinal and alternate osteons during cyclic loading
    Ascenzi, A
    Ascenzi, MG
    Benvenuti, A
    Mango, F
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (07) : 689 - 695
  • [9] X-RAY-DIFFRACTION ANALYSIS OF TRANSVERSAL OSTEONIC LAMELLAE
    ASCENZI, A
    BIGI, A
    RIPAMONTI, A
    ROVERI, N
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1983, 35 (03) : 279 - 283
  • [10] EVIDENCE OF A STATE OF INITIAL STRESS IN OSTEONIC LAMELLAE
    ASCENZI, A
    BENVENUTI, A