A randomised trial of fibrin sealant in peripheral vascular surgery

被引:38
作者
Milne, AA
Murphy, WG
Reading, SJ
Ruckley, CV
机构
[1] SE SCOTLAND BLOOD TRANSFUS SERV,ACAD UNIT,EDINBURGH EH1 2QW,MIDLOTHIAN,SCOTLAND
[2] UNIV EDINBURGH,VASC SURG UNIT,DEPT SURG,EDINBURGH,MIDLOTHIAN,SCOTLAND
[3] UNIV EDINBURGH,DEPT MED,EDINBURGH,MIDLOTHIAN,SCOTLAND
[4] SCOTTISH NATL BLOOD TRANSFUS SERV,PROD SERV DEPT,EDINBURGH,MIDLOTHIAN,SCOTLAND
关键词
D O I
10.1111/j.1423-0410.1996.tb01328.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In a prospective randomised trial 39 patients undergoing either arterial bypass surgery with a polytetrafluoroethylene (PTFE) bypass graft (n = 18) or aortic aneurysm repair with a woven Dacron graft (n = 21) were randomised either to receive fibrin sealant as a topical haemostatic agent at the arterial anastomosis or to act as control. The main outcome measure was the time taken to achieve haemostasis at the suture line. The median time to achieve haemostasis was 0.5 min (range 0-11 min) in the treatment group and 4 min (range 0-21 min) in the control group. This difference was statistically significant p < 0.014 by the Mann-Whitney test. Immediate haemostasis on release of the clamps was achieved in 13/21 patients in the treatment group and in 4/18 patients in the control group (p = 0.023 by Fisher's exact test). There was no difference in total operative time or operative blood loss. No patients in the treatment group suffered any perioperative thromboembolic event and 1 patient in the control group suffered an early graft occlusion. There was no evidence of transmission of hepatitis B or C, or parvovirus B19. In conclusion, fibrin sealant is an effective topical haemostatic agent for arterial suture lines involving PTFE or woven Dacron.
引用
收藏
页码:210 / 212
页数:3
相关论文
共 12 条