Feasibility of a liquid-phase microextraction sample clean-up and liquid chromatographic/mass spectrometric screening method for selected anabolic steroid glucuronides in biological samples

被引:85
作者
Kuuranne, T
Kotiaho, T
Pedersen-Bjergaard, S
Rasmussen, KE
Leinonen, A
Westwood, S
Kostiainen, R
机构
[1] Univ Helsinki, Dept Pharm, Div Pharmaceut Chem, FIN-00014 Helsinki, Finland
[2] United Labs Ltd, Doping Control Lab, Helsinki 00380, Finland
[3] Univ Helsinki, Dept Pharm, Viikki Drug Discovery & Technol Ctr, FIN-00014 Helsinki, Finland
[4] Univ Oslo, Sch Pharm, N-0316 Oslo, Norway
[5] Australian Govt Analyt Labs, Natl Analyt Reference Lab, Pymble, NSW 2073, Australia
来源
JOURNAL OF MASS SPECTROMETRY | 2003年 / 38卷 / 01期
关键词
anabolic steroids; glucuronide conjugates; liquid-phase microextraction; liquid chromatography; tandem mass spectrometry;
D O I
10.1002/jms.393
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml (1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 35 条
[1]  
Bean KA, 1997, J CHROMATOGR B, V690, P65, DOI 10.1016/S0378-4347(96)00403-3
[2]   Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[3]  
Borts DJ, 2000, J MASS SPECTROM, V35, P50, DOI 10.1002/(SICI)1096-9888(200001)35:1<50::AID-JMS912>3.0.CO
[4]  
2-J
[5]   Direct measurement of steroid sulfate and glucuronide conjugates with high-performance liquid chromatography mass spectrometry [J].
Bowers, LD ;
Sanaullah .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :61-68
[6]  
CELOTTI F, 1992, J STEROID BIOCHEM, V43, P469
[7]  
Chang YS, 1996, ANAL LETT, V29, P1389
[8]   Simultaneous determination of urinary androgen glucuronides by high temperature gas chromatography-mass spectrometry with selected ion monitoring [J].
Choi, MH ;
Kim, KR ;
Chung, BC .
STEROIDS, 2000, 65 (01) :54-59
[9]  
Donike M., 1983, Testosterone in sport: leistung und gesundheit, P293
[10]  
Donike M, 1987, INT ATHL FDN WORLD S, P53