Functional neurosurgery in the MRI environment

被引:33
作者
De Salles, AAF
Frighetto, L
Behnke, E
Sinha, S
Tseng, L
Torres, R
Lee, M
Cabatan-Awang, C
Frysinger, R
机构
[1] Univ Calif Los Angeles, Sch Med, Div Neurosurg, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Sch Med, Div Radiol, Los Angeles, CA 90024 USA
[3] Univ Calif Los Angeles, Sch Med, Div Neurobiol, Los Angeles, CA 90024 USA
关键词
deep brain stimulation; globus pallidum; interventional magnetic resonance imaging; subthalamic nucleus; thalamus;
D O I
10.1055/s-2004-830094
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: The purpose of this study was to evaluate the feasibility of microelectrode recording, electrical stimulation, and electrode position checking during functional neurosurgical procedures (DBS, lesion) in the interventional magnetic resonance imaging (iMRI) environment. Methods: Seventy-six surgical procedures for DBS implant or radiofrequency lesion were performed in an open 0.2 T MRI operating room. DBS implants were performed in 54 patients (72 surgical procedures) and unilateral radiofrequency lesions in three for a total of 76 surgeries in 57 patients. Electrophysiological studies including macrostimulation and microelectrode recordings for localization were obtained in the 0.5 to 10 mT fringes of the magnetic field in 51 surgeries. MRI confirmation of the electrode position during the procedure was performed after electrophysiological localization. Results: The magnetic field associated with the MRI scanner did not contribute significant noise to microelectrode recordings. Anatomical confirmation of electrode position was possible within the MRI artifact from the DBS hardware. Symptomatic hemorrhage was detected in two (2.6%) patients during the operation. Image quality of the 0.2 T MRI scan was sub-optimal for anatomical localization. However, image fusion with preoperative scans permitted excellent visualization of the DBS electrode tip in relation to the higher quality 1.5 T MRI anatomical scans. Conclusion: This study shows that conventional stereotactic localization, microelectrode recordings, electrical stimulation, implant of DBS hardware, and radiofrequency lesion placement are possible in the open 0.2 T iMRI environment. The convenience of having an imaging modality that can visualize the brain during the operation is ideal for stereotactic procedures.
引用
收藏
页码:284 / 289
页数:6
相关论文
共 52 条
[1]   MAGNETIC-RESONANCE IMAGE-DIRECTED STEREOTAXIC NEUROSURGERY - USE OF IMAGE FUSION WITH COMPUTERIZED-TOMOGRAPHY TO ENHANCE SPATIAL ACCURACY [J].
ALEXANDER, E ;
KOOY, HM ;
VANHERK, M ;
SCHWARTZ, M ;
BARNES, PD ;
TARBELL, N ;
MULKERN, RV ;
HOLUPKA, EJ ;
LOEFFLER, JS .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :271-276
[2]  
ANZAI Y, 1995, AM J NEURORADIOL, V16, P39
[3]   Radiofrequency ablation of brain tumours using MR guidance [J].
Anzai, Y ;
Lufkin, R ;
DeSalles, A ;
Farahani, K ;
Huang, A ;
Sinha, S ;
Behnke, E ;
Black, K .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1996, 5 (03) :232-242
[4]  
APUZZO M, 1988, STEREOTACTIC NEUROSU
[5]  
BENABID A, 2000, MOVEMENT DISORDER SU
[6]   Near-real-time guidance using intraoperative magnetic resonance imaging for radical evacuation of hypertensive hematomas in the basal ganglia [J].
Bernays, RL ;
Kollias, SS ;
Romanowski, B ;
Valavanis, A ;
Yonekawa, Y .
NEUROSURGERY, 2000, 47 (05) :1081-1089
[7]   Brain tumor surgery with the Toronto open magnetic resonance imaging system: Preliminary results for 36 patients and analysis of advantages, disadvantages, and future prospects [J].
Bernstein, M ;
Al-Anazi, AR ;
Kucharczyk, W ;
Manninen, P ;
Bronskill, M ;
Henkelman, M .
NEUROSURGERY, 2000, 46 (04) :900-907
[8]   Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications [J].
Black, PM ;
Moriarty, T ;
Alexander, E ;
Stieg, P ;
Woodard, EJ ;
Gleason, PL ;
Martin, CH ;
Kikinis, R ;
Schwartz, RB ;
Jolesz, FA .
NEUROSURGERY, 1997, 41 (04) :831-842
[9]  
De Salles Antonio, 1997, P108
[10]  
DESALLES AA, 1998, NEUROSURGICAL OPERAT, P141