Chemiluminescence flow sensor for the monitoring of hydrogen peroxide in rainwater

被引:11
作者
Qin, W
Zhang, ZJ [1 ]
Chen, HH
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Nanjing Univ, Dept Chem, Nanjing 210008, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow sensor; immobilized reagents; ion exchanger; hydrogen peroxide; rainwater;
D O I
10.1080/03067319708028362
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemiluminescence(CL) sensor has been developed for determining hydrogen peroxide in rainwater. The analytical reagents involved in the CL reaction, including luminol and copper ion. were immobilized on anion exchange resin and cation exchange resin, respectively. While a volume of sodium sulphate was passed through a column with immobilized reagents, these two reagents were eluted from the resins and then reacted with hydrogen peroxide in alkaline aqueous solution to produce CL. The CL emission intensity was correlated with the hydrogen peroxide concentration in the range 8 x 10(-8) to 1 x 10(-4) M, and the detection limit was 3.5 x 10(-8) M hydrogen peroxide. Interfering ions present in rainwater were effectively separated on-line by an upstream ion exchanger. A complete analysis, including sampling and washing, could be performed in 1 min with a relative standard deviation of less than 5%. The system was stable for over 200 analyses and has been applied successfully to the determination of hydrogen peroxide in rainwater samples.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 30 条
[1]   PHOTOMETRIC-METHOD FOR THE DETERMINATION OF LOW CONCENTRATIONS OF HYDROGEN-PEROXIDE BY THE PEROXIDASE CATALYZED OXIDATION OF N,N-DIETHYL-P-PHENYLENEDIAMINE (DPD) [J].
BADER, H ;
STURZENEGGER, V ;
HOIGNE, J .
WATER RESEARCH, 1988, 22 (09) :1109-1115
[2]  
BLUM LJ, 1988, ANAL LETT, V21, P717
[3]  
CI Y, 1989, CHINESE J ANAL CHEM, V17, P404
[4]   A NEW CHEMI-LUMINESCENCE ANALYSIS APPARATUS BY MEANS OF A SOLID-STATE PEROXYOXALATE AND IMMOBILIZED FLUOROPHORES [J].
DING, XD ;
WANG, P ;
LIU, GQ .
JOURNAL OF LUMINESCENCE, 1988, 40-1 :844-845
[5]  
FERNANDEZROMERO JM, 1993, ANAL CHEM, V65, P3046
[6]  
FREEMAN T M, 1978, Analytical Chemistry, V50, P1242, DOI 10.1021/ac50031a012
[7]   IMMOBILIZED FLUOROPHORES IN DYNAMIC CHEMI-LUMINESCENCE DETECTION OF HYDROGEN-PEROXIDE [J].
GUBITZ, G ;
VANZOONEN, P ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
ANALYTICAL CHEMISTRY, 1985, 57 (11) :2071-2074
[8]   AMPEROMETRIC FLOW-INJECTION TECHNIQUE FOR DETERMINATION OF HYDROGEN-PEROXIDE AND SULFUR(IV) IN ATMOSPHERIC LIQUID WATER [J].
GUTZ, IGR ;
KLOCKOW, D .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :919-923
[9]  
HLAVAY J, 1993, ACTA CHIM HUNG, V130, P83
[10]   FLUORIMETRIC DETERMINATION OF TRACE HYDROGEN-PEROXIDE IN WATER WITH A FLOW-INJECTION SYSTEM [J].
HWANG, H ;