A continuous film-recirculable drop gas-liquid equilibration device. Measurement of trace gaseous ammonia

被引:21
作者
Genfa, Z [1 ]
Dasgupta, PK [1 ]
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX 79409 USA
关键词
D O I
10.1021/ac000069p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniature Gas-liquid equilibrator or a gas collector, intended as a low-volume interface between a soluble gaseous sample and a liquid phase analyzer or between a liquid phase sample and a detector designed for use with gas samples, is described. This paper addresses the application of the device for the measurement of trace atmospheric ammonia. Gas collection occurs solely by diffusive sampling such that aerosol particles are not collected. The device essentially consists of a tube surrounded externally by a jacket. Gas flows through the jacket and contacts a liquid him flowing on the surface of the tube. The flowing film forms a drop at the tube terminus and is aspirated off through the inner bore of the tube. The collected analyte can be (a) directly sent to an analysis system or (b) preconcentrated on a suitable stationary phase; the preconcentrator effluent can be recycled, if desired, With a fluorometric now injection analysis system harnessed to measure ammonia with such a collector, the limit of detection (LOD, S/N = 3) for a sample drawn for 18 min at 200 mL/min was 4.5 parts per trillion by volume, with the linear range extending up to 30 parts per billion.
引用
收藏
页码:3165 / 3170
页数:6
相关论文
共 37 条
[1]   Heterogeneous production of nitrous acid on soot in polluted air masses [J].
Ammann, M ;
Kalberer, M ;
Jost, DT ;
Tobler, L ;
Rössler, E ;
Piguet, D ;
Gäggeler, HW ;
Baltensperger, U .
NATURE, 1998, 395 (6698) :157-160
[2]   Wet effluent parallel plate diffusion denuder coupled capillary ion chromatograph for the determination of atmospheric trace gases [J].
Boring, CB ;
Poruthoor, SK ;
Dasgupta, PK .
TALANTA, 1999, 48 (03) :675-684
[3]   Simultaneous flame ionization and absorbance detection of volatile and nonvolatile compounds by reversed-phase liquid chromatography with a water mobile phase [J].
Bruckner, CA ;
Ecker, ST ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3465-3470
[4]   ANALYTICAL-CHEMISTRY IN A LIQUID-FILM DROPLET [J].
CARDOSO, AA ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2562-2566
[5]   Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide [J].
Cardoso, AA ;
Liu, HH ;
Dasgupta, PK .
TALANTA, 1997, 44 (06) :1099-1106
[6]   DESIGN AND PERFORMANCE OF A HIGH-VOLUME COMPOUND ANNULAR DENUDER [J].
COUTANT, RW ;
CALLAHAN, PJ ;
KUHLMAN, MR ;
LEWIS, RG .
ATMOSPHERIC ENVIRONMENT, 1989, 23 (10) :2205-2211
[7]  
CURTIS MA, 1988, LC GC-MAG SEP SCI, V6, P158
[8]   A multiple parallel plate wetted screen diffusion denuder for high-flow air sampling applications [J].
Dasgupta, PK ;
Ni, LZ ;
Poruthoor, SK ;
Hindes, DC .
ANALYTICAL CHEMISTRY, 1997, 69 (24) :5018-5023
[9]   A DIFFUSION SCRUBBER FOR THE COLLECTION OF ATMOSPHERIC GASES [J].
DASGUPTA, PK .
ATMOSPHERIC ENVIRONMENT, 1984, 18 (08) :1593-1599
[10]  
DASGUPTA PK, 1993, ACS SYM SER, V232, P41