Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement

被引:36
作者
O'Brien, E [1 ]
机构
[1] Beaumont Hosp, Blood Pressure Unit, Dublin 9, Ireland
[2] Beaumont Hosp, ADAPT Ctr, Dublin 9, Ireland
关键词
mercury; sphygmomanometers; automated devices; device validation; European Society of Hypertension; conventional sphygmomanometry;
D O I
10.1097/00126097-200302000-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
After a little more than a century of use, the conventional Riva-Rocci/Korotkoff technique of measuring blood pressure with a mercury sphygmomanometer and stethoscope, is now being relegated to the museum shelves. Affectionately attached though we may be to this clinical measurement, we must acknowledge that the technique is fraught with inaccuracy and that the age of technology has brought more accurate alternative methodologies. However, we must ensure that the automated devices that are replacing the conventional technique are validated independently for accuracy. The Working Group on Blood Pressure Monitoring of the European Society of Hypertension has recently published an International Protocol to facilitate the validation of more automated devices than was possible with the earlier more complicated protocols.
引用
收藏
页码:19 / 21
页数:3
相关论文
共 15 条
[1]   Quality control of the blood pressure phenotype in the European Project on Genes in Hypertension [J].
Kuznetsova, T ;
Staessen, JA ;
Kawecka-Jaszcz, K ;
Babeanu, S ;
Casiglia, E ;
Filipovsky, J ;
Nachev, C ;
Nikitin, Y ;
Peleska, J ;
O'Brien, E .
BLOOD PRESSURE MONITORING, 2002, 7 (04) :215-224
[2]  
LEHANE A, 1980, BRIT MED J, V4, P1603
[3]   The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomised trials [J].
Moher, D ;
Schulz, KF ;
Altman, DG .
LANCET, 2001, 357 (9263) :1191-1194
[4]  
O'Brien, 1997, Blood Press Monit, V2, P31
[5]   Will the millimetre of mercury be replaced by the kilopascal? [J].
O'Brien, E .
JOURNAL OF HYPERTENSION, 1998, 16 (03) :259-261
[6]   Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults [J].
O'Brien, E ;
Pickering, T ;
Asmar, R ;
Myers, M ;
Parati, G ;
Staessen, J ;
Mengden, T ;
Imai, Y ;
Waeber, B ;
Palatini, P ;
Atkins, N ;
Gerin, W .
BLOOD PRESSURE MONITORING, 2002, 7 (01) :3-17
[7]  
O'Brien E, 2001, HYPERTENSION, V38, pE19
[8]   Blood pressure measuring devices: recommendations of the European Society of Hypertension [J].
O'Brien, E ;
Waeber, B ;
Parati, G ;
Staessen, J ;
Myers, MG .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7285) :531-536
[9]  
O'Brien E., 1993, J HYPERTENSION S2, V11, P43, DOI DOI 10.1097/00004872-199306000-00013
[10]  
O'Brien Eoin, 1991, V14, P1