One step microelectroelution concentration method for efficient coupling of sodium dodecylsulfate gel electrophoresis and matrix-assisted laser desorption time-of-flight mass spectrometry for protein analysis

被引:29
作者
Clarke, NJ
Li, F
Tomlinson, AJ
Naylor, S
机构
[1] Mayo Clin & Mayo Fdn, Dept Biochem & Mol Biol, Biomed Mass Spectrometry Facil, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Pharmacol & Clin Pharmacol, Rochester, MN 55905 USA
关键词
D O I
10.1016/S1044-0305(97)00242-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The coupling of the widely used separation technique of conventional sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) with the mass accuracy measurement capability of mass spectrometry (MS) provides a very powerful analytical technique. However, at present, there is no simple, definitive method for coupling the two methods. Typically, separated proteins are extracted from the gel, either as the native protein or as a peptide mixture after in-gel proteolytic digestion, and then analyzed by mass spectrometry. However, the various extraction techniques described previously have been labor intensive and require a large number of steps. The mass spectrometry analysis of very low concentrations of in vivo derived proteins requires minimum sample handling and on-line concentration. Therefore, we have developed an efficient microelectroelution technique that is applied in a single step manner and contains an on-line concentration device. Initial results from this system have shown a high efficiency of analyte elution from the gel and a simple, robust technique for the coupling of SDS-containing gels with MALDI-TOF-MS analysis and a capability of analyzing proteins at the subpicomole level. (C) 1998 American Society for Mass Spectrometry.
引用
收藏
页码:88 / 91
页数:4
相关论文
共 23 条
[1]   PEPTIDE-MAPPING BY CNBR DEGRADATION ON A NITROCELLULOSE MEMBRANE WITH ANALYSIS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY [J].
BAI, J ;
QIAN, MG ;
LIU, YH ;
LIANG, XL ;
LUBMAN, DM .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1705-1710
[2]   RAPID MASS-SPECTROMETRIC PEPTIDE SEQUENCING AND MASS MATCHING FOR CHARACTERIZATION OF HUMAN-MELANOMA PROTEINS ISOLATED BY 2-DIMENSIONAL PAGE [J].
CLAUSER, KR ;
HALL, SC ;
SMITH, DM ;
WEBB, JW ;
ANDREWS, LE ;
TRAN, HM ;
EPSTEIN, LB ;
BURLINGAME, AL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (11) :5072-5076
[3]   MASS-SPECTROMETRIC ANALYSIS OF BLOTTED PROTEINS AFTER GEL-ELECTROPHORETIC SEPARATION BY MATRIX-ASSISTED LASER DESORPTION IONIZATION [J].
ECKERSKORN, C ;
STRUPAT, K ;
KARAS, M ;
HILLENKAMP, F ;
LOTTSPEICH, F .
ELECTROPHORESIS, 1992, 13 (9-10) :664-665
[4]  
HABEL S, 1995, PROTEIN SCI, V4, P394
[5]  
HARE PE, 1977, METHOD ENZYMOL, V43, P3
[6]   AUTOMATION OF MICRO-PREPARATION AND ENZYMATIC CLEAVAGE OF GEL ELECTROPHORETICALLY SEPARATED PROTEINS [J].
HOUTHAEVE, T ;
GAUSEPOHL, H ;
MANN, M ;
ASHMAN, K .
FEBS LETTERS, 1995, 376 (1-2) :91-94
[7]  
KONIGSBERG WH, 1983, METHOD ENZYMOL, V91, P254
[8]   SURFACTANT EFFECTS ON PROTEIN-STRUCTURE EXAMINED BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
LOO, RRO ;
DALES, N ;
ANDREWS, PC .
PROTEIN SCIENCE, 1994, 3 (11) :1975-1983
[9]   Sensitivity and mass accuracy for proteins analyzed directly from polyacrylamide gels: Implications for proteome mapping [J].
Loo, RRO ;
Mitchell, C ;
Stevenson, TI ;
Martin, SA ;
Hines, WM ;
Juhasz, P ;
Patterson, DH ;
Peltier, JM ;
Loo, JA ;
Andrews, PC .
ELECTROPHORESIS, 1997, 18 (3-4) :382-390
[10]   Mass spectrometry of proteins directly from polyacrylamide gels [J].
Loo, RRO ;
Stevenson, TI ;
Mitchell, C ;
Loo, JA ;
Andrews, PC .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1910-1917